Doctoral Thesis
DOI
https://doi.org/10.11606/T.85.2006.tde-04062007-151052
Document
Author
Full name
Andrea Sanchez
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
Santos, Adimir dos (President)
Caldas, Linda Viola Ehlin
Deppman, Airton
Louzada, Mario Jefferson Quirino
Rodrigues, Laura Natal
Title in Portuguese
"Projeto e confecção de simuladores oftálmicos para aplicações clínicas"
Keywords in Portuguese
braquiterapia
código MCNP
placas oftálmicas
Abstract in Portuguese
Este trabalho apresenta uma metodologia de cálculo para a obtenção de doses em estruturas do olho humano, como: esclera, coróide, retina, nervo óptico, corpo vítreo, câmara anterior, lente, além do tumor devido ao tratamento com placas oftálmicas. Construiu-se um modelo de olho humano com suas principais estruturas e dimensões fieis, além de um modelo matemático para uma placa de Co-60 e uma placa de sementes de I-125, levando-se em conta tamanho e disposição geométrica das fontes reais, com o código de Monte Carlo MCNP-4C. Esse modelo é capaz de calcular as distribuições de dose axiais e radiais para qualquer ponto do olho e para cada uma de suas estruturas. Construiu-se, também, um simulador de acrílico para o olho. Esse simulador é formado por uma esfera de acrílico fatiada em lâminas de 1 mm de espessura para simular as mesmas condições de simulação realizada pelos código MCNP-4C, fornecendo as doses axiais e radiais em filmes radiográficos. O simulador foi utilizado para validar os cálculos realizados com o código MCNP-4C. Os dados obtidos desse modelo matemático servirão para montar um banco de dados de doses para todas as estruturas do olho, posições e tamanhos de tumores e quaisquer placas oftálmicas utilizadas para tratamento. Esse banco de dados será a parte principal para a construção de um “software" nacional para cálculos de dose, que poderá fazer parte de um sistema de planejamento confiável para ser utilizado em radioterapia/braquiterapia.
Title in English
DESIGN AND CONSTRUCTION OF OPHTHALMIC SIMULATORS FOR CLINICAL APPLICATIONS
Keywords in English
brachytherapy
eye plaques
MCNP code
Abstract in English
This work presents a calculational methodology for dose determination in human eye structures, such as: sclera, choroid, retina, lens, vitreous body, optic nerve and disc, and cornea, as well as tumor due to treatment to the eye plaques. A human eye model was constructed taking into consideration its main structural and dimension characteristics. Beyond that a mathematical model for the Co-60 and I-125 plaques with all geometric details were built employing the MCNP-4C code. This model is able to calculate the axial and radial doses in any point of the eye and for each of its structures. An acrylic eye simulator was also built with the aim to obtain experimental results for the both model validations. This simulator is made of an acrylic sphere split into foils of 1 mm thickness which allow the introduction a radiographic film to measure the axial and radial doses. The experimental data were used to validate the MCNP-4C results. The data from the mathematical model will serve as the basis to build a data bank for all the eye structures allowing different position and sizes of tumor as well as the replacement of all ophthalmic plaques used in the treatment. This data bank will be the principal part for the construction of a national software for the dose calculation and can be of great help for a reliable treatment system planning in radiotherapy/brachytherapy.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
AndreaSanchez.pdf (1.05 Mbytes)
Publishing Date
2007-06-22
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors