Titre en portugais
Desenvolvimento de cálculo de unidades monitoras para IMRT
Mots-clés en portugais
IMRT
radioterapia
unidade monitora
Resumé en portugais
A verificação de forma independente do cálculo de dose e de unidades monitoras num plano de tratamento de IMRT é um passo importante nos procedimentos de garantia de qualidade da técnica em questão. Atualmente este verificação é baseada apenas em medidas experimentais demoradas e trabalhosas. Neste trabalho foi desenvolvido uma metodologia de cálculo de unidades monitoras de forma independente como uma nova ferramenta para garantir a qualidade e exatidão dos tratamentos de IMRT. Os valores encontrados se aproximam bastante dos valores calculados pelo sistema de planejamento utilizado, de forma que o algoritmo de cálculo desenvolvido apresentou uma concordância dentro de ± 1,8 % para uma geometria simples. Após diversos testes e com os níveis de ação devidamente estabelecidos, a verificação independente da unidade monitora para planos de tratamento de IMRT se tornará uma ferramenta efetiva e eficiente no controle de qualidade que ajuda a identificar e reduzir possíveis erros de tratamento em radioterapia. Como contribuição original deste trabalho, assegura-se aos serviços de Radioterapia a utilização da metodologia desenvolvida como ferramenta de controle de qualidade em tratamentos com IMRT. Em especial aos serviços que não dispõem de recursos econômicos para adquirirem softwares comercialmente disponíveis para o cálculo independente da unidade monitora.
Titre en anglais
Developement of monitor unit calculation in IMRT
Mots-clés en anglais
IMRT
monitor unit
radiotherapy
Resumé en anglais
Independent verification of dose calculations and monitor units settings of IMRT treatment plans is an important step in the quality assurance procedure for IMRT technique. At present, the verification is mainly based on experimental measurements, which are time consuming and laborious. In this work an independent methodology of monitor units calculation was developed as a new tool for IMRT treatments quality and precision assurance. The values found are near those calculated by the treatment planning system used, in a manner that the calculation algorithm demonstrated ± 1,8 % concordance in a simple geometry with the system. After several tests and the levels of action well established, the independent monitor units verification for IMRT treatment plans will become an effective and efficient tool in quality assurance, helping identification and the reduction of possible mistakes in radiotherapy treatments. To radiotherapy services is assured the use of the developed methodology as a tool of quality control in IMRT treatments as an original contribution of this work, specially those that do not dispose financial resources to acquire commercially available independent monitor unit calculus software.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2012-04-04
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.