• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2011.tde-02032012-134504
Documento
Autor
Nombre completo
Amanda Juliene da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2011
Director
Tribunal
Carneiro, Janete Cristina Gonçalves Gaburo (Presidente)
Medeiros, Regina Bitelli
Sordi, Gian Maria Agostino Angelo
Título en portugués
Avaliação da dose ocupacional oriunda dos procedimentos especiais guiados por fluoroscopia: cateterismo cardíaco
Palabras clave en portugués
dose ocupacional
fluoroscopia
radioproteção
Resumen en portugués
A principal finalidade deste estudo foi avaliar a dose efetiva recebida pelos profissionais de saúde no setor de hemodinâmica de um hospital universitário, na cidade de São Paulo. Para delinear o perfil dos profissionais de saúde foi utilizado um questionário auto-aplicável considerando as variáveis sociodemográficas e variáveis relacionadas ao trabalho em presença de radiação ionizante. A avaliação das doses ocupacionais foi realizada por meio de consulta aos históricos de dose individual do banco de dados da instituição, durante os anos de 2000 a 2009. Um total de 240 registros foi avaliado, envolvendo 38 profissionais ativos (2009), de diferentes categorias profissionais, entre elas, médicos, enfermeiros, tecnólogos em radiologia e auxiliares de enfermagem. As doses efetivas anuais foram comparadas com os limites estabelecidos pelas autoridades regulatórias nacionais. Com base nas doses recebidas e registradas durante o período estudado, foram selecionados cinco médicos para usar mais um dosímetro termoluminescente (em caráter experimental) na mão esquerda, durante a realização dos procedimentos de hemodinâmica. Além disso, foram averiguados os procedimentos de radioproteção adotados pelos profissionais de saúde da instituição estudada. Este estudo permitiu traçar o perfil da equipe médica que integra o serviço de hemodinâmica assim como conhecer a distribuição de suas doses em relação aos limites ao longo dos anos.
Título en inglés
Evaluation of occupational dose from the special procedures guided by fluoroscopy: cardiac catheterism
Palabras clave en inglés
fluoroscopy
occupational dose
radioprotection
Resumen en inglés
The purpose of this study was to evaluate the dose received by health professionals in the hemodynamic sector of a university hospital in São Paulo city. A self-applied questionnaire was used to delineate the profile of health professionals, taking into account sociodemographic variables and variables related to the work with ionizing radiation. The assessment of occupational doses was performed by consulting of the individual dose records of the institution database from 2000 to 2009. A total of 240 records was evaluated, corresponding to 38 active professionals (2009), divided in different professional category: physician, nurses, radiologic technologists and nursing assistants. The annual doses were compared with the limits established by national regulatory authorities. Based on the effective doses received and recorded during the studied period, experimental measures were performed with TL dosimeters in five physicians to evaluate the equivalent dose, in the left hand, during hemodynamic procedures. In addition, the radioprotection measures adopted by health professionals were verified. This study allowed delineating the profile of medical staff that integrates the hemodynamic service as well as knowing the distribution of their doses in relation to limits over the years.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-04-04
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.