Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2006.tde-01062007-135709
Documento
Autor
Nombre completo
Gabriel Issa Jabra Shammas
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2006
Director
Tribunal
Manzoli, José Eduardo (Presidente)
Martini, Sandro
Tenório, Eik
Título en portugués
"Simulação semi-empírica da resposta termoluminescente sob diferentes geometrias de filtro"
Palabras clave en portugués
Dependência Energética
Dosimetria
termoluminescência
Resumen en portugués
Muitos materiais termoluminescentes têm sido desenvolvidos e utilizados para a monitoração individual externa de fótons, mas nenhum tem todas as características desejadas sozinho. Estas características incluem robustez, alta sensibilidade, independência de resposta quanto à energia do fóton, larga faixa de detecção de energia, boa reprodutibilidade, evanescência pequena e curva de emissão termoluminescente simples, com picos abaixo de 150oC. O dosímetro de sulfato de cálcio dopado com disprósio CaSO4:Dy) tem sido usado por muitos laboratórios, principalmente no Brasil e na Índia. Outro fósforo interessante é o fluoreto de cálcio (CaF2). As vantagens destes fósforos começam a ser mais requisitadas e suas desvantagens mais aparentes, no mercado globalizado mais e mais competitivo. Estes fósforos são utilizados em monitoração de área e ambiental devido à sua maior sensibilidade do que outros fósforos, como o LiF:Mg. A sua maior desvantagem é a forte dependência energética da resposta, que deve ser corrigida para suas aplicações em campo, onde o fóton é desconhecido a priori. Um modo interessante de fazer esta correção numa incidência ortogonal da radiação no fósforo é a interposição de um filtro plano vazado entre o feixe e o fósforo. Com o objetivo de reduzir a dependência energética sob incidência em qualquer ângulo, reduzindo a incerteza de medição da dose em campo também, este trabalho apresenta um estudo de simulação em geometrias de filtro esféricas. Foram simuladas irradiações de fótons com raios gama do cobalto 60, com raios-X de 33, 48 e 118 keV, em vários ângulos de incidência de zero a noventa graus. Estas simulações computacionais semi-empíricas, utilizando diferenças finitas em três dimensões, foram feitas em coordenadas esféricas. Os resultados indicaram as melhores espessuras e larguras para a otimização da correção da dependência energética.
Título en inglés
SEMI-EMPIRICAL SIMULATION OF THERMOLUMINESCENT RESPONSE UNDER DIFFERENT FILTER GEOMETRIES
Palabras clave en inglés
dosimetry
energetic dependence
thermoluminescent
Resumen en inglés
Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproductibility, small fading and simple glow curve with peaks above 150oC. Calcium Sulfate Dysprosium doped (CaSO4:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF2). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the field, where photon radiation is unknown a priori. An interesting way do make this correction in orthogonal incidence of the radiation on the phosphor is to interject a plane leaked filter between the beam and the phosphor. In order to reduce the energetic dependence on any incidence angle, reducing the field dose measurement uncertainty too, this work presents a simulation study on spherical filter geometries. It was simulated photon irradiations with Gamma rays of 60Co and x-rays of 33; 48 and 118 keV, on many incidence angles from zero to ninety degrees. These semi-empirical computational simulations using finite differences in three dimensions were done in spherical coordinates. The results pointed out the best filter thicknesses and widths, in order to optimize the correction on energetic dependence.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.