• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.82.2009.tde-29062010-112929
Document
Auteur
Nom complet
Alessandro Márcio Hakme da Silva
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2009
Directeur
Jury
Alves, José Marcos (Président)
Barbosa, Marcello Henrique Nogueira
Silva, Orivaldo Lopes da
Titre en portugais
Análise morfométrica 2D e 3D de amostras de osso trabecular utilizando microtomografia tridimensional por raio-X
Mots-clés en portugais
Análise morfométrica 2D e 3D
Microtomografia tridimensional ('mü'CT)
Osso trabecular
Qualidade óssea
Tensor anisotropia
Resumé en portugais
Ossos trabeculares possuem uma microestrutura porosa e podem ser modelados como um sólido elástico linear, heterogêneo e anisotrópico. A microtomografia tridimensional por raios-x (uCT) tem sido mundialmente utilizada para a caracterização de osso trabecular em pesquisas relacionadas à qualidade óssea e à doenças do metabolismo ósseo como a osteoporose. Na literatura há poucas investigações comparando as análises morfométricas 2D e 3D de osso trabecular. Nesta investigação amostras de osso trabeculares cilíndricas extraídas da cabeça femoral bovina foram utilizadas para a comparação dessas análises por 'mü'CT. O software CT-Analyser foi utilizado para medidas em três direções (crânio-caudal, lateral-medial e anterior-posterior) de diversos parâmetros da microestrutura trabecular tais como espessura trabecular, separação trabecular, número trabecular e os autovalores do tensor de anisotropia (M). A comparação entre os valores dos parâmetros medidos por análises morfométricas 2D e 3D foi realizada pelo teste-t pareado com nível de significância p < 0,05 e por correlação linear de Pearson. Os autovalores da matriz M mostram que a microestrutura trabecular bovina tem uma tendência para a simetria transversalmente isotrópica. Os resultados obtidos mostram que a microtomografia tridimensional por raios-X é uma técnica de grande potencial para caracterização da qualidade óssea gerando bons parâmetros para o diagnóstico de doenças do metabolismo ósseo.
Titre en anglais
2D and 3D morphometric analysis of trabecular bone using X-ray tridimensional microtomography ('mü'CT)
Mots-clés en anglais
2D and 3D morphometric analysis
3D X-ray microtomography ('mü'CT)
Bone quality
Fabric tensor
Trabecular bone
Resumé en anglais
Trebecular bones have a porous microstructure and can be modeled as a linear elastic solid, heterogenous and anisotropic. The x-ray tridimensional microtomography ('mü'CT) has been worldwide used for the assessment of trabecular bone in investigations related to bone quality and aimed to the diagnostic of bone metabolic diseases such as osteoporosis. In the literature few investigations have compared the 2D and 3D morphometric analysis of trabecular bone. In this investigation cylindrical trabecular bone samples were harvested from bovine head femur to carry out that comparison by 'mü'CT. The CT-Analyser software was used to measure in three directions (superior-inferior, lateral-medial and anterior-posterior) several microstructural trabecular parameters such as trabecular thickness, trabecular separation, trabecular number and the eigenvalues of the fabric tensor (M). The comparison between the parameters values measured by 2D and 3D morphometric analysis was performed by the paired-sample t test with a level of significance p < 0,05 and the Pearson's linear correlation. The eigenvalues show that the bovine trabecular microstructure has a tendence to transverse isotropy symmetry. The results show that x-ray tridimensional microtomography ('mü'CT) is a technique of great potential for characterization of generating good bone quality parameters for the diagnosis of diseases of bone metabolism.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2010-09-02
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.