Full name
Flávio Ferraz de Campos Junior
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2015
Supervisor
Committee
Pizzolitto, Elisabeth Loshchagin (President)
Simioni, Bruna Leite
Storti, Anísio
Bernardi, Adilson Cesar Abreu
Souza, Clovis Wesley Oliveira de
Title in Portuguese
Avaliação da citotoxicidade in vitro da liga níquel-berílio às células bacterianas e à linhagem celular NCTC clone 929
Keywords in Portuguese
Berílio
Células NCTC 929
Citotoxicidade
Ligas metálicas
Níquel
Resistência bacteriana
Abstract in Portuguese
A contaminação de equipamentos e materiais hospitalares por microrganismos potencialmente infecciosos e altamente resistentes aos antibióticos incitam grupos de pesquisa e industrias ao redor do mundo a produzir novos materiais, e que estes possuam propriedades capazes de inibir ou eliminar (quase que completamente) a permanência desses patógenos sobre sua superfície. O objetivo deste trabalho foi avaliar a citotoxicidade da liga níquel-berílio quando em contato com as cepas bacterianas de Staphylococcus aureus (ATCC 25932), Staphylococcus epidermidis (ATCC 12228), Pseudomonas aeruginosa (ATCC 27853), Klebsiella pneumoniae (amostra clínica) e Escherichia coli (ATCC 11775), após diferentes períodos de incubação, e em contato com a linhagem celular NCTC Clone 929, célula de tecido conectivo de camundongo. Para realização destes ensaios, foram confeccionados corpos de prova da liga níquel-berílio, com aproximadamente 10,0 mm e diâmetro e 3,0 mm de espessura. Para metodologia de citotoxicidade as células bacterianas preparou-se um inóculo bacteriano de 109 Unidades Formadoras de Colônia por mililitro. Para cada bactéria, um inóculo bacteriano foi preparado e deste, 40 μl foram aplicados em um swab estéril e espalhado no corpo de prova, onde foram introduzidos em placas de Petri, deixados a temperatura 20°C, por diferentes períodos de exposição (1, 3, 6, 9, 12, 18, 24 e 72 horas). Este teste foi realizado em triplicata. Após cada período de tempo, os corpos de prova eram pressionados contra o meio de cultura Agar Mueller-Hinton, em dez diferentes pontos da placa. O método de difusão em Agar foi utilizado para verificar a citotoxicidade da liga níquel-berílio à linhagem celular NCTC clone 929. Os resultados obtidos demonstram uma maior resistência a liga níquel-berílio das bactérias gram-positivas (S. aureus e S. epidermidis) quando comparadas com as gram-negativas (P. aeruginosa, K. pneumonia e E. coli). Destas últimas citadas, a E. coli foi a única que sobreviveu até a sexta hora de exposição, quando em contato de uma hora com o corpo de prova. Todavia, os S. aureus e S. epidermidis foram capazes de resistir até a décima segunda hora em contato com a liga níquel-berílio. Contudo, a partir deste período de incubação, nem mesmo os estafilococos toleraram a presença desses íons. Quando analisados os resultados de citotoxicidade, a liga não apresentou qualquer efeito citotóxico as células NCTC clone 929, sendo classificadas como índice de zona (IZ) zero. Os dados obtidos demonstram que a liga possui propriedades antibacteriana contra as células bacterianas testadas e que não possui nenhum efeito tóxico à linhagem celular NCTC clone 929. Além disso, a liga NiBe mostrou-se mais citotóxica contra as bactérias gram-negativas.
Title in English
Evaluation of in vitro cytotoxicity of nickel-beryllium alloy the bacterial cells and cell line NCTC clone 929
Keywords in English
Alloys
Bacterial resistance
Beryllium
Cytotoxicity
NCTC 929 cells
Nickel
Abstract in English
The contamination of equipment and hospital supplies for potentially infectious microorganisms and highly resistant to antibiotics encourage research groups and industries around the world to produce new materiais, and they have properties able to inhibit or eliminate (almost completely) to stay these pathogens on its surface. The objective of this study was to evaluate the cytotoxicity of nickel-beryllium alloy when in contact with the bacterial strains of Staphylococcus aureus (ATCC 25932), Staphylococcus epidermidis (ATCC 12228), Pseudomonas aeruginosa (ATCC 27853), Klebsiella pneumoniae (clinical sample) and Escherichia coli (ATCC 11775), after different periods of incubation, and in contact with the cell line NCTC Clone 929, connective tissue of mouse cell. For these assays were prepared coupons of nickel-beryllium alloy, with approximately 10.0 mm and diameter and 3.0 mm thick. For cytotoxicity methodology bacterial cells prepared in a bacterial inoculum of 109 Colony-Forming Units per milliliter. For each bacterium, a bacterial inoculum was prepared and this, 40 μl were applied in a sterile swab and spread in the coupons, which were introduced in Petri dishes left at 20°C temperature, for different exposure times (1, 3, 6, 9, 12, 18, 24 and 72 hours). This test was performed in triplicate. After each time period, the samples were pressed against the culture medium Mueller-Hinton Agar at ten different points of the plate. The agar diffusion method was used to assess the cytotoxicity of nickel-beryllium alloy to clone cell line NCTC 929. The results show a greater resistance to nickel-beryllium alloy of gram-positive bacteria (S. aureus and S. epidermidis) compared to gram-negative (Pseudomonas aeruginosa, K. pneumoniae and E. coli). Of the latter mentioned, E. coli was the only one that survived until the sixth hour of exposure when contact an hour with the alloy. However, S. aureus and S. epidermidis were able to hold out until the twelfth time in contact with nickel-beryllium alloy. However, from this incubation period, even staphylococci tolerated the presence of these ions. When analyzed the results of cytotoxicity, the alloy showed no cytotoxic effect the NCTC clone 929 cells, are classified as zone index (IZ) zero. The data obtained show that the alloy possesses antibacterial properties against the tested bacterial cells and has no toxic effect on the cell line NCTC clone 929. Furthermore, 'Ni''Be' alloy was more cytotoxic against gram-negative bacteria.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-03-28
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.