• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.82.2017.tde-24102017-122542
Document
Auteur
Nom complet
Renato Alves Cazon
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 1999
Directeur
Jury
Volpon, José Batista (Président)
Louzada, Mário Jefferson Quirino
Paulin, José Baptista Portugal
Titre en portugais
Ensaio mecânico de compressão axial e flexão em três pontos em complexo tíbio-fibular de ratos adultos jovens
Mots-clés en portugais
Biomecânica
Ensaio mecânico
Rato
Tíbio-fibular
Resumé en portugais
Este estudo teve como objetivo investigar uma provável função mecânica da fíbula no complexo tíbio-fibular de ratos. Para tanto, os complexos tíbio-fibulares de 20 ratos da raça Norvegicus Albinus, variedade Wistar, foram submetidos a esforços de compressão axial e flexão em três pontos. Os animais eram adultos jovens, todos machos com peso corporal médio de 350 g. Foram utilizados 20 pares de tíbias para cada ensaio, sendo que, de um dos lados de cada par, a fíbula foi mantida e, do outro lado, removida. Foi utilizado uma máquina universal de ensaio para a realização de ambos os ensaios mecânicos. Os valores foram obtidos na forma de carga versus deformação (ensaio de compressão), e carga versus deflexão (ensaio de flexão). Os seguintes parâmetros foram analisados: carga máxima, deformação máxima e rigidez. Da análise dos resultados foi concluído que a fíbula, no rato, não aumenta a resistência do complexo tíbio-fibular. Assim, a presença da fíbula parece estar mais relacionada com função de inserções musculares do que fortalecimento tíbio-fibular.
Titre en anglais
Mechanical testing in compression and three point flexion of the rat tibiofibular complex
Mots-clés en anglais
Biomechanics
Mechanical test
Rat
Tibiofibular complex
Resumé en anglais
This study was conducted to investigate the contribution of the fibula to the mechanical resistance of the tibiofibular complex in the rat (both banes are fused distally). Twenty adult wistar rats were used as donor animals of twenty paired tibias. For each pair of bones in one side the fibula was excited and in the other side it was maintained. In a test machine the mechanical tests were done in three flexion and axial compression. The results were plotted either in load x deformation or load x deflection graphs the following parameters were analysed: ultimate load, ultimate deformation and rigidity. It was concluded that the fibula does not increase the mechanical strength of the tibiofibular complex, but it may play a role as an anchorage for the muscles that act on the foot.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-10-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.