• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.82.2017.tde-23102017-153545
Document
Author
Full name
Adriana dos Santos Barone Moreira
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2000
Supervisor
Committee
Defino, Helton Luiz Aparecido (President)
Salata, Luiz Antonio
Volpon, José Batista
Title in Portuguese
Estudo da influência das dimensões dos grânulos de hidroxiapatita na integração óssea
Keywords in Portuguese
Grânulos
Hidroxiapatita
Osteointegração
Abstract in Portuguese
Este estudo teve como finalidade analisar experimentalmente a aplicação de diferentes tamanhos de grânulos de hidroxiapatita em falhas ósseas produzidas em ambos os fêmures de ratos machos da raça Wistar e investigar as correlações dos tamanhos dos grânulos com a quantidade de tecido ósseo neoformado. Cada falha óssea foi preenchida com um dos três tamanhos de grânulos de hidroxiapatita utilizados neste estudo (212 μ, 500μ e 1000μ). Os animais foram divididos em 3 grupos experimentais compostos por 15 animais cada, sendo que cada grupo foi sacrificado de acordo com a data do sacrifício: 30, 90 e 180 dias de período de pós-operatório, respectivamente e posteriormente submetidos ao estudo histológico. No terceiro grupo experimental, foi também realizado estudo radiológico no período de pós-operatório imediato, aos 30, 90 e 180 dias. O grupo controle, composto por 10 animais, que não tiveram preenchimento de suas falhas ósseas , foram submetidos aos estudos histológico e radiológico nos mesmos períodos que o terceiro grupo experimental. De acordo com os resultados dos estudos radiológico e histológico, concluiu-se que a hidroxiapatita empregada foi biocompatível, no entanto, atrasou o processo de reparação óssea na falha, enquanto que o grupo controle apresentou os melhores resultados, com completa reorganização da falha óssea com apenas 90 dias de período de pós-operatório.
Title in English
not available
Keywords in English
Granules
Hydroxyapatite
Osteointegration
Abstract in English
This study evaluated the hydroxyapatite granules osteointegration in defects produced on both femurs of Wistar rats. The defects were filled with one of the three different sizes of hydroxyapatite granules (212μ, 500μ and 1000μ). The rats were divided in 3 groups of 15 animals, which were sacrificed at 30, 90 and 180 days after the operation, followed by histological study of the femurs and radiological study ofthe latter group. The control group, of 10 animals, had no fllling of it's defects and had radiological study and were sacrificed at 180 days after the operation, followed by histological study. It concludes from radiological and histological studies that all sizes of hydroxyapatite granules applied were biocompatible, although it delayed the bone repair. In this study the bone restoration was better observed on the control group.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-10-25
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.