Disertación de Maestría
DOI
https://doi.org/10.11606/D.82.2005.tde-23032006-163502
Documento
Autor
Nombre completo
Suraya Gomes Novais Shimano
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2005
Director
Tribunal
Volpon, José Batista (Presidente)
Fontoura Filho, Carlos
Mazzer, Nilton
Título en portugués
Comportamento mecânico e análise dimensional de parafusos corticais de aço inoxidável e liga de titânio submetidos a ensaios de torção
Palabras clave en portugués
aço inoxidável
comportamento mecânico
liga de titânio
parafusos corticais
torção
Resumen en portugués
Parafusos corticais são uns dos implantes mais utilizados na prática cirúrgica e são normalmente compostos por ligas metálicas como o aço inoxidável F-138 e a liga de titânio 6Al-4V e, quando inseridos no organismo humano, são submetidos a diversos esforços mecânicos. Assim, é necessário avaliar as propriedades mecânicas desses implantes. Portanto, o objetivo deste estudo foi analisar o comportamento mecânico de parafusos corticais de aço inoxidável e de liga de titânio, de fabricação nacional, em ensaio de torção. Vinte parafusos de aço inoxidável foram divididos em quatro grupos (1,2,3,4) e o mesmo foi feito com os parafusos de liga de titânio. Primeiramente, suas medidas-padrão foram analisadas de acordo com a Norma Brasileira NBR ISO 5835:1996. Nos dois grupos 1 (de aço inoxidável e de liga de titânio), o ângulo de rotação foi mensurado por um goniômetro e o ensaio de torção foi manual. Já os parafusos dos dois grupos 2 foram ensaiados em uma máquina de torção. Os parafusos dos grupos 3, primeiramente, foram inseridos em cortical óssea suína e, posteriormente submetidos à torção. Nos dois grupos 4, os parafusos foram submetidos à torção sucessiva e, posteriormente submetidos à torção na máquina. Na análise estatística das propriedades mecânicas, os resultados apresentaram diferença significativa no torque no limite de proporcionalidade entre o grupo 1 e os demais grupos de aço inoxidável e entre o grupo 1 e os demais grupos de liga de titânio, sugerindo um possível erro metodológico no ensaio de torção manual. No torque no limite máximo houve diferença significativa entre o grupo 4 de liga de titânio e os grupos 2 e 3, mostrando que a torção sucessiva pode comprometer esta propriedade. Na rigidez torcional, foi demonstrada diferença estatística significativa entre os grupos 1 e 3 de liga de titânio. Na tenacidade torcional, houve diferença significativa entre o grupo 1 e os demais grupos de liga de titânio, entre o grupo 2 e os grupos 3 e 4 de aço inoxidável e entre todos os grupos de aço inoxidável e todos os grupos de liga de titânio. Conclui-se que, em geral, os parafusos de aço inoxidável apresentaram tenacidade torcional superior aos parafusos de liga de titânio, mas nas demais propriedades estes dois biomateriais apresentaram resultados semelhantes
Título en inglés
Mechanical behavior and dimensional analysis of the stainless steel and titanium alloy córtex screws, undergone torsion testing
Palabras clave en inglés
cortical bone screws
mechanical behavior
stainless steel
titanium alloy
torsion
Resumen en inglés
Cortical bone screws are one of the most used implants in the surgical practice and the stainless steel (ASTM F-138) and titanic (6Al-4V) are the most common alloys used to manufacture them. When inserted into the bone such implants undergo several types of mechanical stress and, therefore, it is very useful to know their mechanical behavior. The purpose of the present study was to compare the mechanical properties of cortical bone screws made up of stainless steel and titanic alloy as tested in torsion. Twenty stainless steel screws were divided into four groups (1,2,3,4) and the same was made for the titanic alloy screws. First, the screw dimension were checked in accordance to the brazilian standard regulations. In groups 1 (either stainless steel or titanic alloy) the angle of rotation was measured with a goniometer and the torsion test was manual. For groups 2 the screws were tested in torsion in a testing machine. In groups 3, firstly, the screws were inserted into suine bone and, later, removed and submitted to torsion. In groups 4 the screws were tested in successive loading and unloading cycles in torsion and, later, submitted to torsion. The results showed statistically significant difference for the yield torque among the group 1 and the other groups of stainless steel and among the group 1 and the other groups of titanic alloy, which suggest a possible methodological error in manual torsion. For the ultimate torque there was difference among titanic groups 4, 2 and 3, showing that repeated torsion can affect such property. For the torsional stiffness there was statistical difference between titanic groups 1 and 3. The torsional tenacity was different among the 1 and the other titanic groups, also there was difference among stainless steel groups 2, 3 and 4. Finally, there was statistical difference among all stainless steel and titanic alloy groups, that, in general, the stainless steel screws showed greater torsional tenacity in comparison with the titanic alloy screws, but for the other torsional properties they displayed a similar behavior
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Suaraya.pdf (2.04 Mbytes)
Fecha de Publicación
2006-03-27
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.