Doctoral Thesis
DOI
https://doi.org/10.11606/T.82.2018.tde-20082018-154905
Document
Author
Full name
Deisi Ferrari
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2017
Supervisor
Committee
Azevedo, Fábio Micolis de (President)
Magalhães, Fernando Henrique
Negrão Filho, Ruben de Faria
Parizotto, Nivaldo Antonio
Silva, Orivaldo Lopes da
Title in Portuguese
Capacidade discriminatória e fator de risco de parâmetros eletromiográficos na dor femoropatelar
Keywords in Portuguese
Capacidade discriminatória
Dor femoropatelar
Eletromiografia de superfície
Fator de risco
Abstract in Portuguese
Apesar da dor femoropatelar (DFP) apresentar alta incidência e prognóstico desfavorável, sua etiologia permanece obscura e seu diagnóstico clínico e funcional indefinido. Acredita-se que uma das causas da DFP seja a alteração na ativação dos músculos vasto medial (VM) e vasto lateral (VL), porém são escassos os estudos que investigam parâmetros eletromiográficos no domínio da frequência destes músculos. Portanto, o objetivo é analisar parâmetros da frequência, obtidos por dois métodos de processamento, para identificação de padrões eletromiográficos em mulheres com DFP que apresentem elevada capacidade discriminatória, correlação com a dor e que possam ser considerados como fator de risco. O sinal eletromiográfico dos músculos VM e VL de 80 mulheres (40 mulheres assintomáticas e 40 mulheres com DFP) foi coletado durante a subida de escada. Considerou-se para análise o sinal eletromiográfico correspondente à componente vertical da força de reação do solo (Fz) e à loading rate (LR) da Fz. Os parâmetros eletromiográficos foram comparados entre os grupos e testados quanto à (ao) reprodutibilidade, capacidade discriminatória, associação com a dor e fator de risco. Os resultados evidenciaram que os parâmetros eletromiográficos correspondentes à Fz e a LR da Fz são reprodutíveis e estão alterados em pacientes com DFP. Entretanto, os parâmetros do sinal eletromiográfico correspondente à Fz apresentaram valores altos de correlação com a dor e capacidade discriminatória quando comparados ao segundo processamento. Além disso, a alteração eletromiográfica, representada pela banda de frequência entre 45 e 96 Hz do VL, mostrou ser um possível fator de risco para DFP. Os achados deste estudo mostram uma nova abordagem na interpretação e aplicabilidade das alterações eletromiográficas dos músculos VM e VL, evidenciando que alterações de controle neuromuscular devem ser consideradas no processo de avaliação, tratamento e prevenção da DFP.
Title in English
Discriminatory capacity and risk fator of electromyography parameters in the patellofemoral pain
Keywords in English
Discriminatory capacity
Patellofemoral pain
Risk factor
Surface electromyography
Abstract in English
Despite the patellofemoral pain (PFP) has high incidence and unfavorable prognosis, its etiology remains unclear and clinical diagnosis indefinite. It is believed that one of the causes of PFP is the muscle activation altered of the vastus medialis (VM) and vastus lateralis (VL), however there are few studies that investigate electromyographic parameters in the frequency domain in these muscles. Therefore, the purpose is to analyze parameters of the frequency domain, using two different processing methods, to identify electromyographic patterns in women with PFP that have high discriminatory capacity, correlation with pain and that could be a risk factor. The electromyography signal of the VM and VL muscles of the 80 women (40 pain-free women and 40 women with PFP) was collected during stair ascend. Electromyography signal related to vertical ground reaction force (Fz) and loading rate (LR) of Fz was considered to analysis. Electromyography signal was compared between groups and tested about the reliability, discriminatory capacity, correlation with pain and risk factor. Results evidenced that electromyography signal related to Fz and LR are reliable and altered in women with PFP. However, electromyography signal related to Fz has higher values of correlation with pain and discriminatory capacity than electromyography signal related to LR. Furthermore, the altered electromyography signal, represented by the frequency between 45 and 96Hz of the VL muscles, may be consider a risk factor for PFP. Findings of this study show a new approach for understanding and applicability of the altered electromyography signal of the VL and VM muscles, evidencing that changes in the neuromuscular control should be considered in the assessment, management and prevention of the PFP.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-08-21
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.