• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.82.2017.tde-17102017-112127
Document
Auteur
Nom complet
Cristiane Spolador Pátaro Domingos
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1998
Directeur
Jury
Paccola, Cleber Antonio Jansen (Président)
Engel, Edgard Eduard
Picado, Celso Herminio Ferraz
Titre en portugais
Estudo da resistência mecânica do ligamento cruzado anterior de ratos submetidos à imobilização
Mots-clés en portugais
Ensaio mecânico de tração
Imobilização
Joelho
Ligamento cruzado anterior
Rato
Resistência mecânica
Resumé en portugais
O efeito da imobilização no ligamento cruzado anterior, através de atadura gessada por um período de 6 semanas, foi estudado em ratos machos, adultos da raça Wistar. Para esta análise foram desenvolvidos dispositivos que permitiram a fixação do espécime à Máquina de Ensaio Universal e a realização de ensaio mecânico de tração. Através desta metodologia a tração foi aplicada na interlinha articular, somente na junção osso-ligamento-osso. Os dados obtidos foram analisados, quanto à carga máxima, deformação máxima, e energia absorvida pelo ligamento até o momento da ruptura. Nos resultados obtidos não foi observado diferença estatisticamente significativa na resistência do ligamento cruzado anterior, do membro imobilizado em relação ao membro não imobilizado, o que nos indica que provavelmente um período de 6 semanas de imobilização o qual permite pequeno grau de movimento como é o caso da imobilização gessada, não foram suficientes para produzir alterações na resistência ligamentar.
Titre en anglais
Immobilization effects on strength of the rat anterior cruciate ligament
Mots-clés en anglais
Anterior cruciate ligament
Immobilization
Knee
Rat
Strength mechanics
Tensile mechanical test
Resumé en anglais
The effects of immobilization through plaster cast for 6 weeks on the mechanical properties of the anterior cruciate ligament (ACL) of Wistar adult mate rats were analysed. Special grips for retaining the specimens during traction tests in a universal test machine were developed. In this way, traction forces could be applied directly to bone-ligament-bone complex. Maximal load, maximal deformation, stiffness and absorbed energy up to the rupture point were considered, compared to the contralateral (normal) ACL. No significant difference could be demonstrated leading us to the conclusion that, at least for the considered lenght of time of immobilization (6 weeks), no important changing in the mechanical properties of the LCA occurred. This contradictory result compared to others in the literature was imputed to the different methodology here employed, where the forces could be applied directly to bone-ligament-bone complex, instead of the femur, anterior cruciate ligament and part of tibia. In addition, the relativily short period by immobilization and the movement permited by the slack immobilization could also be responsabilite for the results.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-10-17
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.