• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.82.2013.tde-16062014-153409
Document
Auteur
Nom complet
José Ricardo Camilo Pinto
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2013
Directeur
Jury
Rollo, João Manuel Domingos de Almeida (Président)
Fortulan, Carlos Alberto
Morais, Dionei Freitas de
Rigo, Eliana Cristina da Silva
Vieira, Edson Del Rio
Titre en portugais
Avaliação hidrodinâmica de uma válvula neurológica ajustável por acionamento mecânico
Mots-clés en portugais
Biomateriais
Derivação ventrículo-peritoneal
Hidrocefalia
Líquor
Teste hidrodinâmico
Válvula neurológica
Resumé en portugais
A hidrocefalia é uma doença ocasionada pelo distúrbio na formação, circulação ou absorção do líquido cefalorraquidiano (líquor) que acarreta na elevação da pressão intracraniana. O tratamento mais usual para a disfunção é a derivação ventrículo-peritoneal (DVP) responsável pela drenagem do líquor do ventrículo até o abdômen do paciente, através do implante de um cateter ventricular, uma válvula neurológica e um cateter peritoneal. Desse modo, o presente estudo apresenta o conceito de uma nova válvula neurológica com um mecanismo inovador para alteração da pressão de funcionamento, com um menor custo produtivo e de possível aceitação pelo Sistema Único de Saúde (SUS). A norma ISO 7197 forneceu as diretrizes atendidas no desenvolvimento da válvula neurológica ajustável e as informações para a construção das bancadas de testes, utilizadas para a realização dos ensaios hidrodinâmicos no protótipo do dispositivo valvular. Foram pesquisados os biomateriais empregados na fabricação de válvulas neurológicas comerciais, para a proposição dos materiais necessários para a construção da válvula ajustável por acionamento mecânico proposta. O aparato utilizado nos testes hidrodinâmicos apresentou incertezas experimentais, que não comprometem os resultados e a avaliação do desempenho in vitro do dispositivo testado. O protótipo da válvula resistiu aos testes de vazamento e de refluxo de fluido. As pressões de abertura e de fechamento apresentaram-se adequadas para o início e a interrupção do escoamento na DVP. Também foi obtido o comportamento do diferencial de pressão, em função da vazão, para as quatro classes de funcionamento disponíveis no protótipo testado. A avaliação hidrodinâmica do protótipo da válvula ajustável por acionamento mecânico apresenta resultados satisfatórios no controle da drenagem de líquor, frente a todos os ensaios hidrodinâmicos realizados.
Titre en anglais
Hydrodynamic evaluation of an adjustable neurological valve by mechanical drive
Mots-clés en anglais
Biomaterials
CSF
Hydrocephalus
Hydrodynamic test
Neurological valve
Shunt
Resumé en anglais
Hydrocephalus is a disease caused by disturbance in formation, circulation or absorption of cerebrospinal fluid (CSF) which causes high intracranial pressure. The most common treatment for the dysfunction is the ventricle-peritoneal shunt responsible for drainage of cerebrospinal fluid from the patient's ventricle to the abdomen, through the implant of a ventricular catheter, a neurological valve and a peritoneal catheter. Thus, the present study introduces the concept of a new valve with an innovative mechanism to change the working pressure, with a lower cost of production and possible acceptance by the Brazilian Health System. ISO 7197 provided the guidelines met in the development of adjustable neurological valve and the information for the construction of testing rigs, used for hydrodynamic testing on the valve device prototype. Biomaterials used in manufacturing commercial neurological valves have been researched for proposition of materials needed for the proposed adjustable neurological valve by mechanical drive. The apparatus used in hydrodynamic tests presented experimental uncertainties, which do not compromise the results and evaluation of in vitro performance of the device tested. The prototype of the valve withstood the leak and the fluid backflow testing. The opening and closing pressures were suitable for the beginning and the interruption of the flow in the ventricle-peritoneal shunt. It was also obtained the behavior of the pressure differential, due to the flow, for the four classes of operation available in the prototype tested. Hydrodynamic evaluation of the prototype of the adjustable valve by mechanical drive shows satisfactory results in the control of CSF drain, dealing with all hydrodynamic tests carried out.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2014-06-18
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.