Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.82.2016.tde-12022016-154421
Document
Auteur
Nom complet
Fernando Alexandre Abrahão
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2002
Directeur
Jury
Defino, Helton Luiz Aparecido (Président)
Picado, Celso Hermínio Ferraz
Vialle, Luiz Roberto Gomes
Titre en portugais
Estudo da influência da técnica de preparação dos pedículos vertebrais na resistência ao arrancamento dos implantes
Mots-clés en portugais
Coluna vertebral
Pedículo vertebral
Teste biomecânico
Resumé en portugais
Foi realizado estudo experimental, utilizando-se vértebra de suínos, para o estudo da influência da técnica de perfuração do pedículo vertebral na resistência ao arrancamento dos implantes. A técnica de perfuração com broca seguida de macheamento do canal pedicular (técnica 1) foi individualmente comparada com as demais: perfuração com broca sem macheamento do canal pedicular (técnica 2), perfuração com fio de Kirschner com macheamento do canal pedicular (técnica 3), perfuração com sonda sem macheamento do canal pedicular (técnica 4). Três grupos experimentais foram utilizados de acordo com a preparação do orifício. O grupo I comparou a técnica 1 com a técnica 2, no qual foi estudado a influência do macheamento no canal do pedículo. O grupo II comparou a técnica 1 com a técnica 3, no qual foi estudado a influência no modo de preparo do orifício utilizando fio de Kirschner. O grupo III comparou a técnica 1 com a técnica 4, no qual foi estudado a influência da utilização da sonda no preparo do orifício. O resultados da comparação da técnica. de perfuração do orifício de acordo com os parâmetros estudados (carga máxima de arrancamento, rigidez, carga no limite de proporcionalidade, deslocamento máximo e deslocamento no limite de proporcionalidade), mostraram que não houve diferença estatisticamente significante entre as diferentes técnicas utilizadas para o preparo dos orifícios do pedículo vertebral na resistência ao arrancamento dos implantes.
Titre en anglais
not available
Mots-clés en anglais
Biomechanical testing
Spine
Vertebral pedicle
Resumé en anglais
An experimental study was conducted on swme vertebrae to investigate the effect of the technique of vertebral pedicle perforation on the pullout resistance of the implants. The technique of perforation with a burr followed by tapping of the pedicular canal (technique 1) was individually compared to the remaining ones, i.e., perforation with a burr without tapping of the pedicular canal (technique 2), perforation with a Kirschner wire with tapping of the pedicular canal (technique 3), and perforation with a probe without tapping of the pedicular canal (technique 4). Three experimental groups were used according to orifice preparation. Group I was used to compare technique 1 to technique 2, with a study of the effect of tapping on the pedicular canal. Group II was used to compare technique 1 with technique 3, with a study of the effect of mode of orifice preparation using a Kirschner wire. Group III was used to compare technique 1 to technique 4, with a study of the effect of the use of a probe for orifice preparation. Comparison of the techniques of orifice preparation according to the parameters studied (maximum pullout load, stiffness, load in the proportionality limit, maximum dislocation, and dislocation in the proportionality limit) showed no statistically significant difference between the various techniques used for preparation of the orifices of the vertebral pedicle, in terms of their effect on the pullout resistance of the implants.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-02-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.