Disertación de Maestría
DOI
https://doi.org/10.11606/D.76.2004.tde-28042004-184322
Documento
Autor
Nombre completo
Fernando Fernandes Paiva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2004
Director
Tribunal
Tannus, Alberto (Presidente)
Rabbani, Said Rahnamaye
Schneider, Jose Fabian
Título en portugués
"Metodologia de imagens de NMR que utiliza um único pulso adiabático de inversão."
Palabras clave en portugués
Pulsos Adiabáticos
Ressonância Magnética Nuclear
Resumen en portugués
Baseado em uma seqüência já conhecida de Multislice Spin Echo convencional, implementamos uma seqüência do tipo Modified Driven Equilibrium Fourier Transform (MDEFT) adiabática multislice em um sistema de 2T e um de microimagens (9.4T). Essa metodologia utiliza, como pulso de inversão, um pulso de RF com modulação em amplitude e freqüência, conhecido por pulso adiabático. Dessa forma, os tempos de inversão são iguais para todos os planos selecionados, resultando num contraste por T1 uniformemente distribuído ao longo dos mesmos. O uso de um único e longo pulso adiabático de inversão tem, ainda, a vantagem de utilizar uma potência de pico menor para operar da mesma forma que um grupo de m pulsos convencionais. Utilizamos pulsos cujas modulações correspondentes de fase e freqüência foram calculadas com base nas condições de “Offset Independent Adiabaticity" (OIA) e a real eficiência dos mesmos foi avaliada através de simulações e experimentalmente. Para realização dos testes da metodologia desenvolvemos e caracterizamos dois “phantoms", cujas imagens demonstram a aplicabilidade da metodologia nos dois sistemas utilizados.
Título en inglés
"NMR imaging methodology using a single adiabatic inversion pulse."
Palabras clave en inglés
Adiabatic Pulses
Nuclear Magnetic Resonance
Resumen en inglés
Based on the conventional Multislice Spin Echo pulse sequence, we implemented an adiabatic multislice Modified Driven Equilibrium Fourier Transform (MDEFT) pulse sequence on a 2T and a 9.4T microimaging system. This methodology uses, as inversion pulse, an amplitude and frequency modulated RF pulse, known as adiabatic pulse. In that way, the inversion times are the same for all slices, resulting in an evenly distributed T1 contrast. A single and long adiabatic inversion pulse has in addition the advantage of using a reduced peak power to perform in the same way as the group of m conventional pulses. We used pulses whose corresponding phase and frequency modulations were based on Offset Independent Adiabaticity and their real efficiency were evaluated both through simulations and experimentally. To test the methodology, we developed and characterized two phantoms, whose images demonstrate the applicability of the methodology in the two mentioned systems.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Dissertfernando.pdf (2.93 Mbytes)