• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.76.2005.tde-21022014-151110
Document
Auteur
Nom complet
Rogério Ferreira Xavier
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2005
Directeur
Jury
Tannus, Alberto (Président)
Bonagamba, Tito Jose
Colnago, Luiz Alberto
Thiemann, Otavio Henrique
Villar, Jose Daniel Figueroa
Titre en portugais
Desenvolvimento de metodologia de supressão de solvente por espectroscopia localizada por RMN(1H MRS) utilizando pulsos de RF adiabáticos com aplicação em medidas de açúcares em frutas
Mots-clés en portugais
Espectroscopia localizada
Pulsos adiabáticos
Ressonância magnética nuclear
Resumé en portugais
Novas seqüências para supressão de contribuições indesejadas em Imagens e Espectroscopia por Ressonância Magnética Nuclear, tais como as provenientes da água, um solvente que sempre resulta num sinal muito intenso em sistemas biológicos, são motivos de estudo e desenvolvimento com diversas aplicações atuais. O método que estamos propondo aqui, uma versão adiabática de MEGA incorporada nas seqüências PRESS e STEAM, visa a supressão do sinal da água presente no espectro de um volume localizado em uma amostra intacta. Para o campo magnético desse estudo (2.0 Tesla) e pelas características do magneto usado nesses experimentos, o pico do solvente tem o inconveniente de apresentar uma linha espectral muito larga quando comparado com a extensão do deslocamento químico das fiações de açúcar. O resultado indesejado é a sobreposição pelas suas vertentes, das diversas outras linhas espectrais, cujo interesse é de extrema importância, como a de alguns sólidos solúveis de açúcares. O principal problema encontrado é que a separação entre os picos da água e dos açúcares próximos é da ordem de 1 ppm. A metodologia proposta consiste na aplicação de pulsos de gradiente de campo magnético intensos em conjunto com uma seqüência de pulsos de RF adiabáticos e convencionais, seletivos em freqüência e espacialmente, para suprimir o pico da água em uma região espectral muito específica, sem nenhum dano a linearidade de fase do espectro restante. Esse procedimento, aliado a uma localização espacial muito eficiente, aumenta ainda mais o poder de análise desta ferramenta, a 1H MRS. Os resultados obtidos em campo de 2.0Tesla (85 Hz/ppm) mostraram que as seqüências híbridas adiabáticas MEGA-PRESS e MEGA-STEAM são bem eficazes na supressão do pico da água, como era esperado. Além disso, sua aplicação no monitoramento do grau de maturação de frutas intactas através do seu teor de açúcar, se mostrou muito bom dadas as condições experimentais extremamente limiares apresentadas pelo espectrômetro
Titre en anglais
Development of Solvent Suppression Localized Volume MR Spectroscopy (1H MRS) using Adiabatic RF Pulses with application on fruit sugar quantification
Mots-clés en anglais
Adiabatic Pulses
Localized Spectroscopy
Nuclear Magnetic Resonance
Resumé en anglais
New sequences for suppression of undesirable contributions in Magnetic Resonance Imaging and Spectroscopy, such as water, a solvent that always represent a very strong peak in biological systems, are object of recent development for several different applications. The method proposed here, an adiabatic version of MEGA incorporated within PRESS and STEAM, aims the suppression of the water peak present on volume selected spectra of intact specimens. For the magnetic field of this study (2.0 Tesla) and for the characteristics of the magnet used in the experiments, the solvent peak has the inconvenience of having a large width as compared to the spread in chemical shift of the sugar fractions. The undesirable result is the superposition on its tail with severa1 spectral lines, whose interest is of extreme importance, such as some sugar solid solutes. The main problem encountered is that the separation between the water peak and the nearest sugar peaks is of the order of 1 ppm. The proposed methodology consists on the application of intense gradient pulses along with a sequence of adiabatic and conventional RF pulses, both frequency and spatially selective, to suppress the water peak in a very specific spectral region, without any disturbance of the phase linearity of the remaining part of the spectrum. This procedure, allied to a very efficient spatial localization, enhances the power of the very well-known tool, the 1H MRS. Results obtained at 2.0Tesla (85 Hz/ppm) show that the hybrid adiabatic sequences MEGA-PRESS and MEGA-STEAM are efficient on suppressing the water peak, as expected. Also, their application on monitoring the degree of ripeness of intact fruits through their sugar content, has shown very good results, considering the extremely limiar experimental conditions presented by the spectrometer
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
RogerioXavierD.pdf (6.23 Mbytes)
Date de Publication
2014-02-25
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.