Full name
Newton Sá de Miranda Curi
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 1998
Supervisor
Committee
Slaets, Annie France Frere (President)
Hornos, Yvone Maria Mascarenhas
Roda, Valentin Obac
Rodrigues, Antonio Ricardo Droher
Torre Neto, André
Title in Portuguese
Controle de qualidade em radiologia: um novo instrumento para avaliação do tamanho do ponto focal e das características operacionais
Keywords in Portuguese
Avaliação de parâmetros radiológicos
Imagens médicas
Raios X
Abstract in Portuguese
Neste trabalho desenvolvemos um dispositivo que determina automaticamente a localização do centro do feixe de raios X e permite uma correta avaliação dos parâmetros dos sistemas radiológicos sem necessidade de alinhamento. O dispositivo desenvolvido-é baseado em sensores de silício; dispositivos mecânicos que executam uma varredura sobre o campo de raios X e computador portátil que analisa e apresenta os resultados no local da avaliação
Title in English
Not available
Keywords in English
Not available
Abstract in English
In this work we developed a device that determines the location of the center of the X ray beam automatically and allows a correct evaluation of the parameters of radiologic systems without the need for alignment. The developed device is based on silicon photodiodes; mechanical devices that execute a scanning on the field of X rays and portable computer that analyzes and presents the results for evaluation
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
NewtonCuriD.pdf (6.78 Mbytes)
Publishing Date
2015-03-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.