Tesis Doctoral
DOI
https://doi.org/10.11606/T.76.1995.tde-17042009-131327
Documento
Autor
Nombre completo
Liliane Ventura
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1995
Director
Tribunal
Castro Neto, Jarbas Caiado de (Presidente)
Lunazzi, José Joaquim
Sanches, Rosemary
Sousa, Sidney Julio de Faria e
Zezell, Denise Maria
Título en portugués
Sistema de medidas automáticas de vícios de refração ocular.
Palabras clave en portugués
Auto-refrator
Vícios de refração ocular
Resumen en portugués
Este trabalho tem como finalidade o desenvolvimento de um sistema objetivo e automático de medidas de vícios de refração ocular. Para tanto, a forte interação entre a Física e a Oftalmologia foi de fundamental importância para que o objetivo fosse atingido. Foram desenvolvidos quatro sistemas, dentre os quais, três são completamente distintos entre si no que se refere aos princípios utilizados para a determinação das ametropias oculares, bem como no que se refere ao modo de detecção da luz retro-espalhada pela retina. O quarto sistema é apenas um refinamento do terceiro que se apresentou eficaz para o uso clínico. O terceiro e quarto sistemas, denominados Sistemas DVL-1 e DVL-2, têm como base a projeção com um laser de diodo de um alvo luminoso no fundo do olho do paciente. Os feixes emergentes do olho testado são divididos em seis partes (três meridianos) e são analisados dois a dois por um CCD (linear no caso do sistema DVL-1 e matricial no caso do sistema DVL-2). A distância entre as duas imagens formadas em cada meridiano fornece o poder de refração naquele meridiano. Com os poderes de refração dos três meridianos (0°, 120° e 240°) é possível determinar o erro refrativo ocular. Testes em réplicas oculares apresentaram uma precisão média de 0,06di (a precisão aceitável para este tipo de exame oftalmológico é de 0,125di) e em olhos in vivo 0,125di para as coordenadas esférica e cilíndrica e 5° para o eixo de astigmatismo, o que está dentro das precisões clínicas necessárias.
Título en inglés
Automatic measuring system of ocular refractive errors.
Palabras clave en inglés
Auto-refractor
Ocular refractive errors
Resumen en inglés
The purpose of the present work is the development of an objective and automatic system for ocular refractive errors measurements. Hence, a strong interaction between Physics and Ophthalmology was fundamentally important in order to provide the success of the work four systems have been developed, where three of them are completely different from each other in the sense of the basic principles used for determining the ocular ametropies, as well as for the detection of the scattered light from the retina. System four is just an improvement of system three, which has presented a good efficiency for clinical use purposes. The third and fourth systems, called DVL-1 and DVL-2 systems, consist on projecting a target in the fundus of the tested eye with a diod laser light. The beams which emerge from the tested eye are divided into six portions (three meridians) and are analyzed in pairs by a CCD (linear CCD for DVL-1 and matrix CCD for DVL-2). The distances between the two images in each meridian provide the refractive power in that particular meridian. As the refractive power is obtained for the three meridians (0°, 120° e 240°), it is possible to determine the ocular refractive error . Tests in artificial eyes have been done and an average error of 0,06di was obtained (0,125di is the allowed precision for this kind of examination). For measurements in vivo eyes a precision of 0,125di for spherical and cylindrical coordinates were obtained, as well as a 5° precision for the axis of astigmatism. These precision values are the ones required by the clinical evaluation.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
LilianeVenturaD.pdf (5.26 Mbytes)