• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.76.2015.tde-16042015-104710
Document
Auteur
Nom complet
Laís Ribovski
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2015
Directeur
Jury
Janegitz, Bruno Campos (Président)
Cavalheiro, Eder Tadeu Gomes
Sotomayor, Maria Del Pilar Taboada
Titre en portugais
Biossensores eletroquímicos para fins ambientais e medicinais
Mots-clés en portugais
Câncer de mama
Compostos fenólicos
Genossensor
Nanobastões de ouro
Tirosinase
Resumé en portugais
Embora exista considerável progresso na área de biossensores, ainda é primordial aprimorar muitos desses dispositivos. Este trabalho tem por objetivo contribuir para o contínuo crescimento dos biossensores a base de enzimas e de moléculas de DNA, sendo dois biossensores eletroquímicos descritos. O primeiro trata-se de um biossensor enzimático utilizando tirosinase (Tyr) imobilizada por intermédio de cistamina (CYS) e glutaraldeído (GA) para a detecção de compostos fenólicos. Eletrodos de carbono impressos (SPCE) foram modificados com nanobastões de ouro (AuNRs) em filme de poli(amido amina) (PAMAM) geração 4 para o favorecimento da transferência direta de elétrons (DET) entre o eletrodo e o sítio ativo da enzima. Para caracterizar os AuNRs e AuNRs-PAMAM, espectroscopia de absorção no UV-Visível, espalhamento de luz dinâmico (DLS) e microscopia eletrônica de varredura (SEM) foram empregadas. As etapas do biossensor foram estudadas por voltametria cíclica e linear, amperometria e microscopia de força atômica (AFM) na presença de dois analitos: catecol (CAT) e dopamina (DA). A faixa linear para CAT foi de 2,8 a 30,3 μmol L-1 com um limite de detecção (LD) de 1,0μmol L-1 enquanto para a DA, a faixa linear foi de 27,8 a 448,7 μmol L-1 e LD de 10,0 μmol L-1. Além de apresentar ótima resposta frente a possíveis interferentes, o sensor também mostrou excelente desempenho em amostras reais, que atrelados aos testes de repetibilidade e reprodutibilidade mostram a estabilidade e acurácia do biossensor. O segundo sensor, trata-se de um sensor de DNA impedimétrico em eletrodo de ouro para a detecção da mutação c.68_69del relacionada à predisposição ao câncer de mama. A imobilização da sequência de captura (SH-ssDNA) no eletrodo ocorreu pela ligação ouro-enxofre (Au-S) e o modelo de hibridização escolhido foi a hibridização direta. O genossensor distinguiu eficientemente entre as sequências alvo (tarDNA) e não-complementar (ncsDNA), apresentando faixa linear de 1,0 a 200,0 nmol L-1 e LD de 0,14 nmol L-1. Os resultados sugerem que ambos biossensores têm potencial e que as estratégias propostas são promissoras para o desenvolvimento de outros biossensores.
Titre en anglais
Electrochemical biosensors to medical and environmental applications
Mots-clés en anglais
Breast cancer
Genosensor
Gold nanorods
Phenolic compounds
Tyrosinase
Resumé en anglais
Despite a considerable progress in the area of biosensors, it is still crucial to improve most of these sensors. This study aims to contribute to the ongoing growth of enzyme- and DNA-based biosensors, being described two electrochemical biosensors. The first one is an enzyme-based biosensor with immobilized Tyrosinase (Tyr), through cystamine (CYS) and glutaraldehyde (GA), for detection of phenolic compounds. Screen-printed carbon electrodes (SPCE) were modified by gold nanorods (AuNRs) stabilized with poly(amide amine) PAMAM generation 4 to facilitate direct electron transfer (DET) between electrode and enzyme active site. AuNRs and AuNRs-PAMAM were characterized using UV-Visible absorption spectroscopy, dynamic light scattering (DLS) e scanning electron microscopy (SEM). Biosensor stages were studied by cyclic and linear voltametry, amperommetry and atomic force microscopy (AFM) and tested agains two analytes: catechol (CAT) and dopamine (DA). Detection limit (LD) for CAT is 1 μmol L-1 and linear range from 2.8 to 30.3 μmol L-1, for DA, LD is 10.0 μmol L-1 and linear range 27.8 to 448.7 μmol L-1. Besides, the biosensor shows great response in the presence of interferents, it also had an excellent performance in real samples that along with repeatability and reproducibility tests indicate stability and accuracy of the biosensor. The second sensor is an impedimetric DNA sensor prepared on gold electrode to detect c.68_69del mutation related to breast cancer predisposition. Capture sequence (HS-ssDNA) immobilization occurred due to gold-sulfur bond (Au-S) and direct hybridization was the chosen hybridization model. The genosensor was able to distinguishing between target sequence (tarDNA) and non-complementary sequence (ncsDNA) and linear range and LD were found to be 1.0 to 200.0 nmol L-1 and 0.14 nmol L-1, respectively. Results suggest both biosensors have potential and proposed strategies are promising for other biosensors development.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-04-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.