Master's Dissertation
DOI
https://doi.org/10.11606/D.76.2010.tde-15072010-094531
Document
Author
Full name
Anderson Silva Chaves
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2010
Supervisor
Committee
Catunda, Tomaz (President)
Martinelli, Marcelo
Misoguti, Lino
Title in Portuguese
Novos resultados teóricos e experimentais para a técnica Z-scan
Keywords in Portuguese
Índice de refração não-linear
Integral de difração de Fresnel-Kirchhoff
Óptica não-linear
Técnica Z-scan
Abstract in Portuguese
O índice de refração não-linear n2 é o parâmetro chave da não-linearidade de terceira ordem em materiais ópticos. Um método simples, direto e sensível para medição do índice de refração não-linear (n2) é a técnica Z-scan proposta Sheik-Bahae et al 1. Nesse trabalho, um estudo sistemático quanto a esta técnica foi realizado. Utilizando a integral de difração de Fresnel-Kirchhoff, foi possível analisar a técnica investigando a influência do raio de abertura da íris. Foram obtidas expressões analíticas inéditas quando consideramos baixas não-linearidades induzidas por amostras finas. Esses resultados mostraram que o valor de n2 obtido é aproximadamente 36% maior do que n2 obtido por Sheik-Bahae para abertura linear de S=0,5, por exemplo.
Extensões da técnica foram feitas, onde simulações para testar a viabilidade de medidas Z-scan no campo próximo e com dois feixes foram realizadas, de onde também foi possível encontrar resultados analíticos inéditos. Esses resultados teóricos foram testados tanto para feixe único quanto duplo em alguns experimentos, sendo obtido um bom acordo. Por fim, um novo método para medição do índice de refração não-linear não-degenerado foi proposto, em que é possível obter n2 no comprimento de onda do feixe de prova, num experimento com dois feixes. Esse resultado é importante uma vez que, em muitos casos, não é possível a realização de uma medida Z-scan convencional, devido ao fato da amostra não absorver o comprimento de onda do feixe de prova. Um resultado de n2 para rubi em 633nm foi obtido em bom acordo com resultados prévios da literatura, em que foram utilizadas técnicas de maior complexidade experimental.
Title in English
Novel theoretical and experimental results to Z-scan technique
Keywords in English
Fresnel-Kirchhoff difraction integral
Nonlinear optics
Nonlinear refractive índex
Z-scan technique
Abstract in English
The nonlinear refractive index n2 is the key parameter of the third order nonlinearity of optical materials. A simple, direct and sensitive measurement of nonlinear refractive index n2 is so-called Z-scan technique proposed by Sheik Bahae et al 1. In this work, a systematic study on this technique was performed. Based on Fresnel-Kirchhoff diffraction integral formula, it was possible to analyze the technique in order to investigate the influence of the apertures radius. We obtained unpublished analytical expressions when we consider small nonlinearities induced by thin samples. These results showed that the value of n2 obtained is about 36% larger than n2 obtained by Sheik-Bahae when the linear opening is 50%, for example.
Extensions about the technique were made. Simulations were performed in order to test the feasibility of near-field Z-scan and two-color Z-scan measurements. Again it was also possible to find unpublished analytical results. The theoretical results were tested in some experiments and good agreement was found. Finally, a new method for measuring the nondegenerate refractive index was proposed. So, there is the possibility to obtain n2 at the wavelength of the probe beam in a two-color Z-scan experiment. This result is important since in many cases is impossible to perform a conventional z-scan measurement, due to the fact that the sample does not absorb the wavelength of the probe beam. A result of n2 for ruby at 633nm was obtained in good agreement with previous studies.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2010-07-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.