Thèse de Doctorat
DOI
https://doi.org/10.11606/T.76.2017.tde-14092017-154855
Document
Auteur
Nom complet
Daniel Martelozo Consalter
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2017
Directeur
Jury
Tannus, Alberto (Président)
Baffa Filho, Oswaldo
Colnago, Luiz Alberto
Gomes Júnior, Francisco Guilhien
Papoti, Daniel
Titre en portugais
Implementação de aquisição paralelas de imagens utilizando bobinas de RF tipo phased array e sampled array
Mots-clés en portugais
Bobinas de RF
MRI
Phased array
Sample array
Resumé en portugais
Técnicas de aquisição paralelas e hardware dedicados vem sendo desenvolvidos desde a década de 1980 para reduzir o tempo de aquisição de imagens via ressonância magnética (IRM). Uma bobina do tipo phased array é um dispositivo do tipo receptor, que usa múltiplas bobinas (canais) cada qual com seu próprio circuito de detecção para adquirir simultaneamente os sinais que formam uma imagem ou espectro via IRM. Exemplos de técnica de imagem paralela que usa bobinas tipo phased array são Sensitivy Enconding (SENSE) e GeneRalized Autocalibrating Partial Parallel Acquisition (GRAPPA). Sampled array é o nome de um método proposto neste trabalho em que cada canal de uma bobina multicanal é responsável por adquirir de forma independente o sinal da sua amostra de modo que cada sinal de amostra é endereçado ao seu canal específico. Neste trabalho, descrevemos o desenvolvimento de uma bobina phased array de quatro canais para anatomia de cabeça de rato usando circuito impresso flexível para operar em um sistema de IRM pré-clínico de 2T com objetivo de validar o método de construção e uso de circuito flexível como bobina de recepção. Também desenvolvemos uma bobina de quatro canais para realizar simultaneamente a imagem de quatro sementes na mesma varredura para validar o método Sampled Array com objetivo de melhorar a qualidade da imagem e simultaneamente acelerar experimentos de múltiplas amostras. Os resultados mostram que a bobina de circuito impresso phased array, em comparação com uma bobina de enrolamento de fio regular, forneceu uma boa relação sinal / ruído (RSR) e possui geometria mais adequada à anatomia por ser flexível. Além disso, o processo de fabricação da bobina seja facilitado desde que toda a bobina é construída como um protótipo de circuito impresso. Os bons resultados da bobina sampled array mostraram o método como promissor para imageamento de múltiplas amostras com aumento de RSR e diminuição de tempo de experimentos em relação ao uso de bobinas de canal único.
Titre en anglais
Development of parallel imaging acquisition using phased array and sample array coils
Mots-clés en anglais
MRI
Phased array
RF coil
Sample array
Resumé en anglais
Parallel techniques and dedicated hardware has been developed since the 1980s to reduce acquisition time on Magnetic Resonance Imaging (MRI) scanners. A phased array is a receiver only mode device concept, which uses multiple channels (coils) with their own detection circuits to simultaneously acquire MRI or localized spectroscopic signals. An example of parallel imaging technique that uses phased array coils is Sensitivy Enconding (SENSE). Sampled array is the name proposed in this work for a method in which each channel of a multichannel coil is responsible to acquire independently the signal from its sample so that each sample signal is addressed to its specific channel. In this work, we describe the development of a four-channel phased array coil for rat head anatomy using flexible printed circuit board (PCB), to operate on a 2T pre-clinical MRI scanner to validate the construction method and usage of flexible PCB as a receiver coil. We also developed a four-channel sample array coil to simultaneously perform the imaging of four seeds at the same scan, to validate the proposed method to improve image quality at the same time accelerating multiple seed imaging for agriculture studies. The results show that phased array PCB coil as compared to a regular wire winding coil provide good signal-to-noise ratio (SNR) imaging with more adequate geometry to the anatomy by being flexible. In addition, the coil manufacturing process is facilitated since the entire coil is constructed as a PCB prototype. The sample array imaging showed as a promising method for multiple sample increasing SNR and time to do experiments.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-10-06
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.