  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.76.1998.tde-13032014-163552
Document
Author
Full name
Caio Chiaradia
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 1998
Supervisor
Committee
Ventura, Liliane (President)
Roda, Valentin Obac
Sousa, Sidney Julio de Faria e
Title in Portuguese
Sistema de medidas de áreas de úlceras de córnea e acompanhamento de suas evoluções para ser utilizado em hospitais
Keywords in Portuguese
Física oftálmica
Imagens oculares
Úlceras de córnea
Abstract in Portuguese
Foi desenvolvido um sistema inédito para diagnóstico e acompanhamento de Doenças Oculares Externas, particularmente de úlceras de córnea e que foi implementado num Hospital-Escola para uso diário. As úlceras de córnea, até então, eram avaliadas de forma subjetiva e qualitativa, estimando-se a extensão da área afetada. O indicativo de evolução do quadro clínico é basicamente a alteração da área afetada. Com o intuito de se poder avaliar a evolução desta patologia de forma quantitativa e padronizada, foi desenvolvido o presente sistema. O sistema consistiu em acoplar a uma Lâmpada de Fenda (biomicroscópio ocular) um divisor de feixes e um sistema ótico, no caminho ótico onde os feixes da Lâmpada de Fenda são paralelos, de forma que a imagem proporcionada nas oculares da Lâmpada de Fenda é simultaneamente proporcionada num detector do tipo CCD. Esta câmera CCD foi acoplada a um micro computador do tipo PC, via uma interface comercial, e as imagens são disponibilizadas num monitor. Um software dedicado foi desenvolvido e possui as seguintes funções e características: reconhecimento automático e medidas das áreas de ulceração, opcionalmente, medidas interativas de áreas quaisquer, medidas lineares interativas de comprimentos quaisquer e um amplo banco de dados dedicado a este setor da Oftalmologia. Ainda, todos os comandos podem ser realizados através do teclado ou do mouse, particularmente o de capturar imagem também pode ser acionado através de um pedal desenvolvido especialmente para o sistema. O sistema apresentou uma precisão de 5% (o método convencional, para medidas de úlceras perfeitamente elípticas proporcionava uma precisão de no máximo 13%). O protótipo do sistema está em uso no Hospital das Clínicas de Ribeirão Preto (ambulatório de Oftalmologia, setor de Doenças Oculares Externas), tem demonstrado excelente desempenho e estudos clínicos, agora proporcionados pela automação do sistema, começam a ser realizados
Title in English
System for measuring corneal ulcers areas and their evolution monitoring to be used in hospitals
Keywords in English
Corneal ulcers
Ocular images
Ophthalmic Physics
Abstract in English
A system for diagnostic and follow up of External Ocular Diseases has been developed, particularly for Corneal Ulcers, and has been implemented in a Hospital-School for daily use. The corneal ulcers, until then, have been evaluated in a subjective and qualitative way, just by estimating the affected area. Its clinical evolution is indicated by the increasing/decreasing of the affected area. In order to evaluate quantitatively and standardize the evolution of this pathology we have developed the present system. The system consisted in attaching to a Slit Lamp (ocular biomicroscope) a beam splitter in the parallel rays optical path and an optical system, in order to provide simultaneously the ocular images to the Slit Lamp ocular lenses and to a CCD camera. The camera has been attached to a PC, via a commercial frame grabber and the images are displayed in a monitor. A dedicated software has been developed and it has the following functions and features: corneal ulcers self recognizing and area measurements, optional interactive area and extension measurement of any image and a data bank dedicated for this sector of the Ophthalmology. Also all the commands are available for keyboard or mouse clicking. Particularly, the image capturing command can also be turned ON/OFF by clicking a pedal, which was specially developed for the system. The precision of the measurements of the system is 5% (the conventional method, for perfect elliptical ulcer areas provides a maximum precision of 13%). The system's prototype is being used in the Hospital das Clínicas de Ribeirão Preto and it has presented excellent performance. Clinical studies are now being able to be done due to the automation of the clinical evaluations
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
CaioChiaradiaM2.pdf (8.65 Mbytes)
Publishing Date
2014-03-17
 