• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.76.1998.tde-11062008-102226
Documento
Autor
Nombre completo
Márcio Alexandre Marques
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1998
Director
Tribunal
Slaets, Annie France Frere (Presidente)
Almeida, Adelaide de
Caldas, Linda Viola Ehlin
Robilotta, Cecil Chow
Tannus, Alberto
Título en portugués
Simulação computacional de parâmetros importantes dos sistemas radiológicos
Palabras clave en portugués
Controle de qualidade
Linguagem C
Ponto focal
Raios X
Simulação computacional
Sistemas radiológicos
Resumen en portugués
A presente pesquisa faz parte de um trabalho que visa o desenvolvimento de um método de simulação computacional que permita fazer a avaliação da qualidade da imagem radiográfica de maneira rápida e completa e que não apresente os problemas dos métodos tradicionais disponíveis e usados atualmente. Neste trabalho foi desenvolvido um método que leva em consideração e simula os parâmetros importantes dos sistemas radiológicos tais como: o tamanho e a distribuição de intensidade do ponto focal, as condições geométricas de exposição, a heterogeneidade do campo, a distribuição angular dos raios X, a grade supressora, bem como o efeito Compton. O método de simulação computacional desenvolvido realiza o controle de qualidade da imagem para um objeto colocado em qualquer posição do campo de radiação. A simulação foi feita implementando os algoritmos desenvolvidos em linguagem "C" e os resultados foram apresentados sob forma gráfica para facilitar a compreensão dos usuários.
Título en inglés
Computer simulation of important parameters of radiological systems
Palabras clave en inglés
C programming language
Computer simulation
Focol spot
Quality control
Radiological systems
X-ray
Resumen en inglés
This research is part of a work that aims the development of a computer simulation method which allows to evaluate the radiographic image quality in a faster and complete way, so that it doesn't present the problems found in the available methods used nowadays. The method developed in this work takes into consideration and simulates the important parameters of the radiologic systems such as: the focal spot size, the intensity distribution focal spot, the geometric conditions exposure, the field heterogeneity, the X-ray angular distribution, the antiscatter grid (Bucky), as well as the Compton effect. This developed computer simulation method achieves the image quality control of an object at any position of the radiation field. The simulation was done implementing the algorithms developed in C language and the results were displayed in a graphic way to facilitate the users comprehension.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
MarcioMarques_D.pdf (5.99 Mbytes)
Fecha de Publicación
2008-06-11
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.