• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.76.2010.tde-11052010-154900
Documento
Autor
Nombre completo
Stella Torres Muller
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2010
Director
Tribunal
Bagnato, Vanderlei Salvador (Presidente)
Acioli, Lucio Hora
Cesar, Claudio Lenz
Cruz, Flávio Caldas da
Magalhães, Daniel Varela
Título en portugués
Padrão de frequência compacto
Palabras clave en portugués
Césio
Espectroscopia Ramsey
Metrologia
Padrão de frequência atômico
Relógio atômico
Resumen en portugués
Apresentamos os aspectos mais relevantes para a construção e caracterização de um padrão primário de tempo e frequência compacto. Nesse sistema a amostra de átomos de referência é preparada a partir de uma armadilha magneto-óptica. Após a obtenção de uma amostra significativa de átomos os feixes laser são desligados e, durante a expansão livre, a nuvem atômica é submetida a uma sequência de pulsos de micro-ondas que caracterizam o método de Ramsey. Os pulsos de micro-ondas são aplicados em uma cavidade de micro-ondas, esculpida dentro da câmara de vácuo. Todo o ciclo de funcionamento é implementado dentro dessa cavidade e por esse motivo o padrão é considerado compacto. Quando os átomos são interrogados com pulsos de τ = 1 ms separados por Τ = 8 ms obtemos uma largura a meia altura da franja central de 52 Hz e uma estabilidade a curto prazo de 10-13. Alguns causadores de deslocamentos de frequência foram avaliados.
Título en inglés
Compact frequency standard
Palabras clave en inglés
Atomic clock
Atomic frequency standard
Cesium
Metrology
Ramsey spectroscopy
Resumen en inglés
We present some relevant aspects for the construction and characterization of a compact primary frequency standard. In this system, the atomic ensemble is prepared with a magnetooptical trap. Once a significant number of cold atoms is obtained, the laser beams are turned off and, during the free expansion, the cloud is submitted to a sequence of two microwave pulses, characterizing the well-known Ramsey method. The microwave pulses are applied in a microwave cavity that was sculpted inside the vacuum chamber. All the working cycle takes place into this cavity. When the atoms are interrogated by two pulses of τ = 1 ms separated by Τ = 8 ms, the linewidth of the central fringe is 52 Hz and a short-term stability 10-13 is observed. Some frequency shifts were evaluated.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2010-05-13
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.