• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.76.2013.tde-04042013-110931
Document
Author
Full name
Diego Lencione
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2013
Supervisor
Committee
Castro Neto, Jarbas Caiado de (President)
Zezell, Denise Maria
Zilio, Sérgio Carlos
Title in Portuguese
Desenvolvimento de sistemas ópticos e modelos radiométricos para otimização sistêmica em retinógrafos de alta resolução
Keywords in Portuguese
Análise de Tolerância
Eliminação de reflexos
Radiometria
Retinografia
Sistemas ópticos
Abstract in Portuguese
O principal intento deste trabalho é demonstrar como a combinação de resultados de modelos radiométricos e de análises do limite de resolução de imagens produzem impactos positivos não apenas no projeto óptico de retinógrafos de alta resolução, mas que também geram ferramentas que auxiliam na definição da arquitetura de todo o equipamento, considerando, inclusive, os limites impostos por normas internacionais para a segurança do paciente em relação a radiação emitida na realização dos exames. Particularmente ao projeto óptico, foram desenvolvidos os sistemas de iluminação e imageamento da retina, onde se destacam duas propostas de metodologias: a primeira para a implementação da técnica de eliminação das bem conhecidas retro-reflexões geradas no conjunto óptico que é comum à iluminação e ao imageamento da retina, e a segunda para a obtenção de soluções efetivas em sistemas imageadores, que prima pela diminuição da sensibilidade dos componentes aos erros que são introduzidos pelos processos de fabricação e montagem. Analisando os resultados obtidos com o protótipo, foram validados os sistemas e modelos propostos, que se tornaram parte integrante de um produto oftalmológico aprovado para a comercialização, o retinógrafo Kiron.
Title in English
Development of optical systems and radiometric models to systemic optimization in high resolution fundus cameras
Keywords in English
Fundus cameras
Optical systems
Radiometry
Reflex elimination
Tolerance analysis
Abstract in English
The fundamental objective of this work is to demonstrate how radiometric models and analysis of the limit of resolution can provide not only positive impacts to the optical project of high resolution fundus cameras, but also creates tools to perform an optimization of all the equipment, considering the limits imposed by international standards to ensure security to the patient regarding the equipment radiation emission. In the optical project in particular, the imaging and illuminating systems of the retina were developed, in which stands out two proposed methodologies: first, to eliminate the well known retro-reflections in the common optical assembly of the imaging and illuminating systems, and a second one that helps the optical designer to find effective solutions in imaging systems, focused in the reduction of the component sensitivity to the fabrication and assembly processes errors. Analyzing the results from the prototypes the systems and the models proposed were validated, becoming integrant part of an ophthalmic product approved for commercialization, the Kiron fundus camera.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2013-04-08
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.