• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.76.1998.tde-18042007-095410
Document
Auteur
Nom complet
Eduardo Ribeiro de Azevêdo
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1998
Directeur
Jury
Panepucci, Horacio Carlos (Président)
Baffa Filho, Oswaldo
Castro Neto, Jarbas Caiado de
Titre en portugais
Efeito do movimento em MRI e implementação das técnicas de Gradient Moment Nulling e pré-saturação especial na redução de artefatos relacionados ao movimento.
Mots-clés en portugais
Artefatos relacionados ao movimento
Compensação de efeitos do movimento
Imagens
Resumé en portugais
A proposta deste trabalho foi analisar os efeitos de movimento em imagens convencionais por ressonância magnética nuclear, bem como implementar e otimizar. as técnicas de "Gradient Moment Nulling" e Pré-Saturação Espacial, utilizadas para eliminação de artefatos relacionados ao movimento. Simulações numéricas foram utilizadas para a análise da influência do movimento dos spins nas imagens e para compreender as bases físicas das técnicas de "Gradient Moment Nulling" e Pré-saturação Espacial. Na técnica de "Gradient Moment Nulling" as amplitudes dos gradientes de compensação dependem do posicionamento dos mesmos na seqüência. Sendo assim, foram propostas algumas configurações para a seqüência e calculadas as amplitudes dos gradientes de compensação. A melhor configuração para a seqüência foi escolhida de modo a minimizar a amplitude dos gradientes. A técnica de "Gradient Moment Nulling" foi testada experimentalmente e os resultados mostraram sua eficacia na redução dos artefatos de "intravoxel dephasing" e misregistration". Na implementação da técnica de Pré-saturação Espacial foram utilizados pulsos de pré-saturação convencionais do tipo Sinc e as limitações na seqüência resultantes desta escolha foram analisadas experimentalmente e via simulações numéricas. A redução do efeitos de "flow related enhacement" e dos artefatos de "Aliasing" na imagens, foi alcançada com sucesso pela técnica de Pré-Saturação Espacial.
Titre en anglais
Motion effects in magnetic resonance imaging and implementation of Gradient Moment Nulling and spatial presaturation for reducing motion related artifacts.
Mots-clés en anglais
Imaging
Motion effects compensation
Motion related artifacts
Resumé en anglais
The purpose of this work was to analyze the effects of motion in conventional Magnetic Resonance Imaging (MRI), and to implement and optimize the Gradient Moment Nulling and Spatial Presaturation techniques, which can be used to minimize the motion related artifacts. Numerical simulations, were used to analyze the influence of the motion on the image and to understand the physics of the above techniques. In the Gradient Moment Nulling method, the compensation gradients amplitudes depends on the their positions in the sequence. To analyze this, some configurations for the sequence were proposed and the corresponding gradients amplitude were calculated. The best configuration for the sequence was chosen to minimize the gradients amplitudes. The sequences were tested experimentally and the results proved their efficacy in reducing the intravoxel dephasing and flow blique misregistration artifacts. Conventional sinc pulse were used in the implementation of the Spatial Presaturation technique and the limitation of this choice was analyzed experimentally and by nurnerical simulation. The reduction of the flow related enhancement and "aliasing" artifacts, was successfully achieved by the Spatial Presaturation technique.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Azevedo.pdf (4.78 Mbytes)
Date de Publication
2007-04-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.