• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.75.2019.tde-27112019-173136
Documento
Autor
Nome completo
Suysia Ramos D'Almeida
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2019
Orientador
Banca examinadora
Buoro, Rafael Martos (Presidente)
Faria, Ronaldo Censi
Paixão, Thiago Regis Longo Cesar da
Sotomayor, Maria Del Pilar Taboada
Título em português
Desenvolvimento de eletrodos compósitos modificados com GO/PVI/PdNPs para determinação de p-nitrofenol em efluentes têxteis sintéticos
Palavras-chave em português
p-nitrofenol
compósito
eletrodo de pasta de carbono
nanopartículas de paládio
óxido de grafeno
poli(vinilimidazol)
redução
Resumo em português

O presente trabalho disserta sobre o desenvolvimento de eletrodos à base de pasta de carbono modificados para a determinação eletroquímica de p-nitrofenol em amostras de efluentes têxteis sintéticos. Eletrodos de pasta de carbono (CPE) foram modificados com um material composto por óxido de grafeno, poli (vinilimidazol) e nanopartículas de paládio (GO/PVI/PdNPs) e caracterizados por Microscopia Eletrônica de Transmissão (TEM) acoplado com espectroscópica eletrônica de dispersão (EDS). A PdNPs foram encontradas bem distribuídas no suporte da matriz polimérica, com tamanho médio de 4,14 ± 1,61 nm. Os CPE foram desenvolvidos e modificados com o compósito nas proporções de 2,5%, 5%, 10% e 25% (m m-1) de GO/PVI/PdNPs: pó de grafite e mantendo 33,3% óleo mineral nujol (mT m-1) a fim de escolher a melhor proporção do modificador. Com base na melhor definição dos picos referentes aos processos anódicos e catódicos, optou-se em usar como modificador o eletrodo, na proporção de 10% (m m-1) na pasta. Este foi caracterizado eletroquimicamente por cronoculometria, voltametria cíclica. Ao modificar o eletrodo com GO/PVI/PdNPs-10% obteve-se um ganho de 2,3 vezes de área eletroativa comparando com CPE. Em resposta analítica as correntes de pico de redução do p-nitrofenol aumentaram linearmente com o aumento das suas concentrações na faixa de 10 a 170 µmol L-1, com R2 igual a 0,997 e os limites de detecção e quantificação (LOD) 2,20 µmol L-1 e (LOQ) 7,32 µmol L-1 para o GO/PVI/PdNPs-10%-CPEe a faixa linear entre 50 a 300 µmol L-1, com R2 igual a 0,982 e (LOD) 15,45 µmol L-1 e (LOQ) 51,56 µmol L-1 para o CPE. O GO/PVI/PdNPs-10%-CPE apresentou maior sensibilidade e menor desvio padrão das medidas comparado com o CPE. O eletrodo modificado permitiu uma boa recuperação para p-nitrifenol nas amostras de efluentes têxtil sintético, com valores de recuperação compreendidos entre 95,06 a 104,61% / (n = 8), atestando a exatidão do método proposto.

Título em inglês
Devolopment of composite eletrode modified with GO/PVI/PdNPs for determination of p-nitrophenol in synthetic textile efluents
Palavras-chave em inglês
p-nitrophenol.
carbon paste electrode
composite
graphen oxide poly(vinylimidazole)
palladium nanoparticles
reduction
Resumo em inglês

The present work discusses the development of modified carbon-based electrodes for the determination of p-nitrophenol in synthetic textile effluent samples using electroanalytical techniques. The carbon paste electrodes (CPE) were modified with a material composed of graphene oxide, poly (vinylimidazole) and palladium nanoparticles (GO/PVI/ PdNPs). The GO/PVI/PdNPs composite was synthesized and characterized by Electron Transmission Electron Microscopy coupled with electron scattering spectroscopy (EDS). The PdNPs were well distributed in the polymer matrix support with an average size of 4 ± 2 nm. The CPE were developed and modified with the nanocomposite in the proportions of GO/PVI/PdNPs: 2.5%, 5.0%, 10.0% and 25.0% (m m-1): graphite powder and maintaining 33.3% mineral oil nujol (mT m-1) in order to choose the best proportion of the modifier. Based on the best definition of the peaks for the anodic and cathodeic processes, it was decided to use the electrode as a modifier in the proportion of 10% (m m-1) in the pulp. This was characterized electrochemically by chronoculometry and cyclic voltammetry. When modifying the GO/PVI/PdNPs-10%-CPE electrode, a gain of 2.3 times of electro-active area was obtained comparing with CPE. In an analytical response, the peak currents of p-nitrophenol reduction increased linearly with increasing concentrations in the range of 10 a 170 µmol L-1, with R2 equal to 0.997 and the limits of detection and quantification (LOD) of 2.20 L-1 and LOQ (7.32 µmol L-1) for (GO/PVI/PdNPs)-10%-CPE and the linear range between 50 and 300 µmol L-1, with R2 equal to 0,982 and (LOD) 15.45 µmol L-1) and (LOQ) 51.56 µmol L-1 for CPE. The GO/PVI/PdNPs-10%-CPE presented higher sensitivity and lower standard deviation of the measurements compared to CPE. The modified electrode allowed a good recovery for p-nitrophenol in the synthetic textile effluent samples, with recovery values ranging from 95.06 to 104.61% / (n = 8), attesting the accuracy of the proposed method.

 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2019-12-12
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.