• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.75.2018.tde-23102018-170956
Document
Auteur
Nom complet
João Victor Basolli Borsatto
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2018
Directeur
Jury
Lanças, Fernando Mauro (Président)
Coltro, Wendell Karlos Tomazelli
Gomes, Paulo Clairmont Feitosa de Lima
Nassur, Maria Eugenia Queiroz
Titre en portugais
Colunas empacotadas em cromatografia líquida capilar: desenvolvimento de hardwares e avaliação de suas contribuições no desempenho cromatográfico
Mots-clés en portugais
alargamento de banda
colunas capilares
colunas empacotadas
hardwares para colunas
partículas superficialmente porosas
partículas totalmente porosas
Resumé en portugais

Essa dissertação de mestrado descreve o desenvolvimento de hardwares de colunas para cromatografia líquida capilar. O processo de desenvolvimentos desses dispositivos é descrito gradativamente e os pontos fortes e as limitações de cada modelo de hardware são discutidos. O melhor modelo de hardware desenvolvido apresentou produção simples, fácil conexão ao sistema cromatográfico e resistência a pressões superiores a 900 bar. Sucessivamente ao estabelecimento de um modelo de hardware apropriado, os efeitos dos materiais do hardware na eficiência das colunas foram avaliados. Poucos estudos relatam a influência do hardware nas separações em escala capilar, de forma que essa dissertação contribui para o preenchimento dessa lacuna. Capilares de aço inoxidável e sílica fundida e frits de aço inoxidável e fibra de vidro foram avaliados. Colunas com eficiências superiores a 100.000 pratos por metro foram produzidas.

Titre en anglais
Packed columns for capillary liquid chromatography: hardware development and evaluation of its contribution to the chromatography performance
Mots-clés en anglais
band broadening
capillary columns
columns hardware
fully porous particles
packed columns
superficially porous particles
Resumé en anglais
This master's dissertation describes the development of hardware for capillary liquid chromatography columns. The development process of the devices is described gradually and the strengths and limitations of each model of hardware are discussed. The best-developed hardware model presented easy production, practice connection to the chromatographic system and resistance to pressures greater than 900 bar. After the establishment of an appropriate hardware model, the effects of hardware materials on the efficiency of the columns were evaluated. Few studies report the influence of the hardware on capillary scale separations; therefore, this dissertation contributes to fill this gap. Capillaries of stainless steel and fused silica and frits of stainless steel and glass fiber were evaluated. Columns with efficiencies greater than 100,000 plates per meter were produced.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2018-10-25
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.