• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.75.2018.tde-22102018-175317
Document
Auteur
Nom complet
Fernando Lindo Silva
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2018
Directeur
Jury
Lanza, Marcos Roberto de Vasconcelos (Président)
Olivi, Paulo
Perez, Joelma
Sales, Lucia Helena Mascaro
Sitta, Elton Fabiano
Titre en portugais
Estudo da eletrogeração de peróxido de hidrogênio utilizando eletrodos de difusão gasosa modificados com 9,10-fenantraquinona para aplicação no tratamento de efluentes contendo os antibióticos am
Mots-clés en portugais
amoxicilina
ampicilina
degradação de antibióticos
eletrodos de difusão gasosa
peróxido de hidrogênio
Resumé en portugais

Fármacos tem sido foco de diversas estudos e pesquisas devido à constatação de sua ocorrência em diversos compartimentos ambientais. Esses compostos, com destaque para os antibióticos, apresentam biodegradação limitada e contínua introdução nos sistemas hídricos devido ao descarte incorreto, eliminação por excreção de parte da dose ingerida e, principalmente, pelo processo de fabricação nas indústrias farmacêuticas. Como as formas convencionais de tratamento têm se mostrado pouco efetivas, a tecnologia eletroquímica associada aos processos oxidativos avançados (POA) têm se mostrado uma maneira eficiente na degradação desses compostos. Em diversos estudos, os eletrodos de difusão gasosa (EDG) são apresentados como uma opção promissora no que diz respeito à eletrogeração de peróxido de hidrogênio, uma das principais fontes de radical hidroxila utilizado nos POA. Nesse aspecto, surgem estudos sobre modificadores que podem atuar como catalisadores nesse processo. Neste trabalho estudou-se o comportamento eletroquímico de dois modificares orgânicos suportados em matriz condutora de carbono Printex 6L. Os compostos orgânicos escolhidos, pertencentes a classe das quinonas, foram a 2-terc-butil-9,10-antraquinona (TBA) e a 9,10 fenantraquinona (FQA). Os estudos foram realizados em um eletrodo de disco/anel rotatório (RRDE), depositando-se uma microcamada porosa, contendo ou não o modificador, sobre o carbono vítreo deste eletrodo. Através dos resultados de voltametria cíclica e linear pode-se avaliar a geração de peróxido de hidrogênio, que foi superior para as microcamadas com adição dos modificadores. O material com 0,5% (m/m) de FQA mostrou-se o mais eficiente entre todos, com 30% de rendimento a mais quando comparado à matriz Printex e 6% maior quando comparada a mesma quantidade de TBA na produção do peróxido. Estudou-se também a eficiência da FQA para a produção de peróxido de hidrogênio (H2O2) a partir da reação de redução do oxigênio gasoso (O2), em eletrodos de difusão gasosa (EDG). Considerando os cinco eletrodos estudados (Printex não modificado e modificado com 0,1, 0,5, 1,0 e 2,0% de FQA) foi realizada uma avaliação sobre qual eletrodo seria o mais apto a ser utilizado nos trabalhos de degradação dos fármacos. Para isso fez-se a análise da concentração de peróxido de hidrogênio eletrogerada, o consumo energético e a cinética envolvida no processo. Os resultados mostraram um aumento significativo na produção de peróxido para os eletrodos modificados com 0,5 e 1,0% de FQA. Sendo que o eletrodo sem modificação atingiu um máximo de 215 ppm de H2O2 em um potencial de -1,4 V com um consumo energético de 29 kWh kg-1 de H2O2. O eletrodo modificado com 0,5% de FQA alcançou 566 pmm de H2O2 em um potencial de -1,4 V com um consumo energético de 14 kWh kg-1 de H2O2. Estudou-se também a degradação dos antibióticos amoxicilina e ampicilina (AMX e AMP) com anodos condutores comerciais de diamante dopados com boro. A influência da densidade de corrente aplicada (15, 30 e 60 mA cm-2) para o mesmo eletrólito de suporte (3 g / L de Na2SO4) e a mesma concentração inicial de antibióticos (100 mg dm-3 cada) foi avaliada. A mineralização total dos antibióticos foi atingida. Além disso, o processo foi encontrado para ser mais eficiente na densidade de corrente de 30 mA cm-2. Os resultados demonstram a importância dos processos eletroquímicos mediados na degradação de AMX e AMP. Esta influência foi confirmada por alguns testes em que a eletrólise foi acoplada à radiação UV ou à radiação ultrassônica. O uso de radiação UV resulta em uma degradação menos eficiente, enquanto que o ultrassom melhora um pouco a taxa de mineralização quando comparado ao processo eletrolítico simples.

Titre en anglais
Study of hydrogen peroxide electrogeneration using gas diffusion electrodes modified with 9,10-phenanthraquinone for use in the treatment of effluents containing the antibiotics amoxicillin and ampicillin
Mots-clés en anglais
amoxicillin
ampicillin
antibiotic degradation
gas diffusion electrodes
hydrogen peroxide
Resumé en anglais

Drugs have been the focus of several studies and researches due to the finding of their occurrence in several environmental compartments. These compounds, especially antibiotics, present limited biodegradation and continuous introduction into water systems because of incorrect disposal, elimination by excretion of part of the ingested dose and, mainly, by the manufacturing process in the pharmaceutical industries. As conventional mode of treatment have been shown to be ineffective, electrochemical technology associated with advanced oxidative processes (POA) has been shown to be an efficient way of degradation of these compounds. In several studies, gas diffusion electrodes (EDG) are presented as a promising option with respect to hydrogen peroxide electrogeneration, one of the main sources of hydroxyl radical used in POAs. In this aspect, studies on modifiers appear that can act as catalysts in this process. In this work the electrochemical behavior of two organic modifiers supported in Printex 6L carbon matrix was studied. The organic compounds chosen, belonging to the class of quinones, were 2-tert-butyl-9,10-anthraquinone (TBA) and 9,10-phenanthraquinone (FQA). The studies were performed on a rotating disk / ring electrode (RRDE), depositing a porous micro-layer, containing or not the modifier, on the glassy carbon of this electrode. Through the results of cyclic and linear voltammetry the generation of hydrogen peroxide can be evaluated, which was superior to the micro-layers with addition of the modifiers. The material with 0.5% (w / w) of FQA was the most efficient of all, with 30% more yield when compared to the Printex matrix and 6% higher when compared to the same amount of TBA in peroxide production . It was also studied the efficiency of the FQA for the production of hydrogen peroxide (H2O2) from the reduction reaction of gaseous oxygen (O2) in gaseous diffusion electrodes (EDG). Considering the five electrodes studied (Printex not modified and modified with 0.1, 0.5, 1.0 and 2.0% of FQA) an evaluation was made on which electrode would be the most suitable to be used in the degradation works of the drugs. For that, the analysis of the hydrogen peroxide concentration, the energy consumption and the kinetics involved in the process were analyzed. The results showed a significant increase in peroxide production for electrodes modified with 0.5 and 1.0% of FQA. Since the unmodified electrode reached a maximum of 215 ppm of H2O2 at a potential of -1.4 V with an energy consumption of 29 kWh kg-1 of H2O2. The electrode modified with 0.5% of FQA reached 566 pmm of H2O2 at a potential of -1.4 V with an energetic consumption of 14 kWh kg-1 of H2O2. The degradation of antibiotics amoxicillin and ampicillin (AMX and AMP) with commercial boron-doped diamond conducting anodes was also studied. The influence of the applied current density (15, 30 and 60 mA cm-2) for the same support electrolyte (3 g / L Na2SO4) and the same initial concentration of antibiotics (100 mg dm-3 each) was evaluated. Total mineralization of antibiotics was achieved. In addition, the process was found to be more efficient at current density of 30 mA cm-2. The results demonstrate the importance of the electrochemical processes mediated in the degradation of AMX and AMP. This influence was confirmed by some tests in which the electrolysis was coupled to UV radiation or to ultrasonic radiation. The use of UV radiation results in less efficient degradation, while ultrasound improves the rate of mineralization somewhat compared to the simple electrolyte process.

 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2018-10-25
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.