• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.75.2015.tde-18082015-104331
Document
Auteur
Nom complet
Rodrigo Nogueira Padovan
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2015
Directeur
Jury
Azevedo, Eduardo Bessa (Président)
Lanças, Fernando Mauro
Dezotti, Marcia Walquíria de Carvalho
Nogueira, Raquel Fernandes Pupo
Olivares, Igor Renato Bertoni
Titre en portugais
Degradação de hormônios em águas de abastecimento público por fotocatálise heterogênea solar
Mots-clés en portugais
Degradação solar
Fotocatálise heterogenia
hormônios
SPE-on line
Resumé en portugais

Vários compostos utilizados ou produzidos pelo homem quando lançados no meio ambiente, ou mesmo em estações de tratamento de esgoto, não são facilmente degradados ou removidos. Desse modo, acabam voltando às estações de tratamento de água, que em sua maioria utilizam métodos que não são capazes de remover tais compostos, podendo até aumentar o efeito biológico destes. A detecção destes compostos é um desafio para a Química Analítica, já que ocorrem em baixas concentrações. Degradou-se uma mistura de quatro hormônios ¾ três naturais, 17 β-estradiol (E2), estrona (E1) e estriol (E3), e um sintético, 17 α-etinilestradiol (EE2) ¾ em água de abastecimento público pela fotocatálise heterogênea solar, utilizando-se o fotocatalisador dióxido de titânio suportado em um reator de placa plana operado com reciclo. Foi também desenvolvido e validado um método analítico totalmente automatizado que possibilitou detectar e quantificar baixas concentrações dos quatro hormônios. Foram obtidos limites de quantificação de 10 μg L-1, com a extração de 125 μL de amostra, com coeficiente de variação (< 20%) e exatidão (todos entre 80 a 120%) dentro dos limites aceitáveis para este tipo de análise. Foi possível verificar que a eficiência de degradação atingiu mais de 90% em menos de 4 horas para todos os hormônios. Mesmo com esse nível de degradação não foi possível a remoção da atividade estrogênica. Só houve uma redução significativa após 9 h de degradação. Possivelmente, a atividade estrogênica foi mantida pela concentração restante dos hormônios e/ou pela formação de produtos de degradação que também apresentavam atividade biológica. Alguns desses compostos foram propostos, sendo alguns conhecidos na literatura. No entanto, com as análises realizadas, não foi possível se ter certeza de que os compostos gerados no tratamento são realmente os sugeridos.

Titre en anglais
Degradation of hormones in drinking water by solar heterogeneous photocatalysis
Mots-clés en anglais
heterogeneous photocatalysis
hormones
solar degradation
SPE-on line
Resumé en anglais

Several compounds used or produced by man, when released into the environment, or even in sewage treatment plants, are not easily degraded or removed. Thus, these compounds eventually return to water treatment plants, which mostly use methods incapable of removing them, and may even enhance their biological effect. The detection of these compounds is a challenge to Analytical Chemistry, as they occur at low concentrations. A mixture of four hormones were degraded ¾ three of them of natural origin, 17β-estradiol (E2), estrone (E1), and estriol (E3) and a synthetic one, 17α-ethinyl estradiol (EE2) ¾ in public water supply by solar heterogeneous photocatalysis, using supported titanium dioxide as the photocatalyst in a flat-plate reactor in recycling mode. A fully automated analytical method was developed and validated making it possible to detect and quantify low concentrations of the four hormones. Quantification limits of 10 μg L-1 were achieved with the extraction of a 125 μL-sample, with coefficients of variation (< 20%) and accuracy (all between 80 and 120%) were acceptable limits for this type of analysis. It was possible to observe that the degradation performance reached more than 90% in less than 4 hours for all hormones. Even with this level of degradation it was not possible to remove the estrogenic activity. There was only a significant reduction after 9 h of degradation. Possibly, the estrogenic activity was maintained by the remaining concentration of the hormones and/or by degradation by-products which still present biological activity. Some of these compounds were proposed, some of which have been already published in the literature. However, with the performed analyses, it was not possible to ascertain that the generated compounds during treatment are actually the ones here suggested.

 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-08-18
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.