• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.75.2012.tde-17042012-164903
Document
Author
Full name
Deodato Peixoto dos Santos
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2012
Supervisor
Committee
Machado, Sergio Antonio Spinola (President)
Lanza, Marcos Roberto de Vasconcelos
Rodrigues, Christiane de Arruda
Title in Portuguese
Determinação eletroquímica de fenóis após processo de degradação de benzeno usando sensor à base de nanotubos de carbono-ftalocianina de cobalto
Keywords in Portuguese
benzeno
ftalocianina
nanotubo de carbono
Abstract in Portuguese
Episódios de contaminação envolvendo hidrocarbonetos de petróleo são relatados com bastante freqüência, principalmente em função dos acidentes envolvendo transporte e estocagem de combustíveis, dentre os quais se destacam o benzeno, tolueno, etilbenzeno e xileno (BTEX). Assim, não é surpreendente o grande número de trabalhos, atualmente disponíveis, relacionados à remediação de águas subterrâneas. Entretanto, é conhecido que a total mineralização de benzeno, na maioria das tecnologias utilizadas para remediação de solos e águas subterrâneas, não ocorre totalmente podendo formar compostos fenólicos altamente tóxicos. Por este motivo, este trabalho teve por finalidade a análise dos subprodutos formados a partir da degradação do benzeno, que são eles: hidroquinona, resorcinol, catecol, fenol, p-benzoquinona. Para este propósito, os compostos fenólicos formados foram medidos utilizando um eletrodo de carbono vítreo modificado com filme de nanotubos de carbono e ftalocianinas metalicas. Os compostos fenólicos também foram analisados por cromatografia liquida de alta eficiência com detector espectrofotométrico, espectrometria no UV/Visível. Os sensores eletroquímicos propostos mostraram-se altamente eletrocatalíticos e sensíveis na determinação dos derivados da oxidação do benzeno, obtendo-se um limite de detecção de 4,54 μmol L-1 para a hidroquinona, de 1,63 μmol L-1 para o resorcinol, 0,14 μmol L-1 para o catecol, 4,19 μmol L-1 para o fenol e 1,78 μmol L-1 para a p-benzoquinona. Observa-se que existem algumas diferenças nos limites de detecção para cada composto fenólico estudado e que o eletrodo GC/MWCNT/CoPc apresentou menores limites de detecção para o catecol, resorcinol e p-benzoquinona podendo analisar predominantemente esses compostos fenólicos a partir da eletro-oxidação do benzeno. A metodologia proposta comparada com os métodos oficiais de análise e foi observado que os sensores atingem os limites mínimos necessários de detecção, demonstrando que sensores eletroquímicos baseados em CNTs tornam-se uma alternativa no desenvolvimento de metodologias altamente sensíveis, rápidas e de baixo custo.
Title in English
Electrochemical determination of phenols after the process of degradation of benzene using sensor based on carbon nanotubes-cobalt phtalocyanine
Keywords in English
benzene
carbon nanotube
phtalocyanine
Abstract in English
Contamination episodes involving petroleum hydrocarbons are reported quite frequently, mainly because of accidents involving transportation and storage of fuels, among which stand out as benzene, toluene, ethylbenzene and xylene (BTEX). Thus, it is not surprising the large number of papers currently available relating to remediation of groundwater. However, it is known that the complete mineralization of benzene, most of the technologies used for remediation of soil and groundwater, it doesn't occur and it can form highly toxic phenolic compounds. For this reason, this paper aims to analyze the products formed from the degradation of benzene, which are: hydroquinone, resorcinol, catechol, phenol, p-benzoquinone. For this purpose, the phenolic compounds formed were measured using a glassy carbon electrode modified with a film of carbon nanotubes and metallic phthalocyanines. Phenolic compounds were also analyzed by high performance liquid chromatography with UV detection, spectroscopy in UV / Visible. The proposed electrochemical sensors were highly sensitive and the electrocatalytic determination of the oxidation of benzene derivatives, obtaining a detection limit of 4.54 μmol L-1 for hydroquinone, 1.63 μmol L-1 for resorcinol , 0.14 μmol L-1 for catechol, 4.19 μmol L-1 for phenol and 1.78 μmol L-1 for p-benzoquinone. It is observed that there are some differences in detection limits for each phenolic compound studied and the electrode GC/MWCNT/CoPc had lower detection limits for catechol, resorcinol and p-benzoquinone can analyze these phenolic compounds predominantly from the electro- oxidation of benzene. The proposed methodology was compared with the official methods of analysis and it was observed that the sensors reach the required minimum limits of detection, demonstrating that electrochemical sensors based on CNTs become an alternative for the development of high sensitivity, rapid and low-cost. methodologies.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2012-07-31
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.