• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.75.2018.tde-16012018-103738
Document
Author
Full name
Viviana da Silva Prado
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2017
Supervisor
Committee
Deflon, Victor Marcelo (President)
Marques Netto, Caterina Gruenwaldt Cunha
Nikolaou, Sofia
Corbi, Pedro Paulo
Marques, Fabio Luiz Navarro
Title in Portuguese
Obtenção de complexos de GaIII e InIII com interesse em medicina nuclear a partir do desenvolvimento de ligantes multidentados
Keywords in Portuguese
gálio
iminas
índio
radiocomplexos
semicarbazonas
tiossemicarbazonas
Abstract in Portuguese
Essa tese consiste na preparação de novos compostos de coordenação de Re, Ga e In como potenciais agentes de diagnóstico. Para a síntese desses complexos, foram propostos novos ligantes tiossemicarbazonas, semicarbazonas e iminas derivadas do 2-hidroxi-3-clorometil-5-metilbenzaldeído, o qual foi preparado a partir do reagente comercial 2,6-bis(hidroximetil)-4-metilfenol com rendimento de 76% após três etapas. Os novos ligantes foram obtidos em duas etapas, N-alquilação e condensação, com rendimentos médios de 60 a 75%, respectivamente. Foram obtidos ligantes tridentados, pentadentados e hexadentados, que podem ser empregados na síntese de uma diversidade de complexos, mostrando a versatilidade do reagente proposto. Os ligantes tridentados não se mostraram apropriados para a obtenção de complexos estáveis de ReV, para os quais a caracterização foi dificultosa. A tiossemicarbazona/piridil, como ligante potencialmente pentadentado, formou complexo com ReV com baixo rendimento e possivelmente instável nas condições estudadas. Os ligantes semi e tiossemicarbazonas hexadentados proporcionaram a formação de complexos com GaIII e InIII, com rendimentos de 60 a 90% e de satisfatória estabilidade. O complexo de GaIII hexacoordenado com a bis(semicarbazona) pôde ser obtido na forma neutra zwitteriônica e na forma catiônica como um sal de nitrato, a partir de [Ga(acac)3] e [Ga(NO3)3], respectivamente. Esse mesmo ligante formou complexo neutro zwitteriônico com InIII, quando empregou-se o precursor [In(acac)3] e uma possível mistura de produtos ao empregar-se o [InCl3]. O congênere radioativo do complexo a bis(semicarbazona) foi obtido com rendimentos quantitativos na marcação a partir do 67GaCl3 em 15 minutos e à temperatura ambiente, apresentando razoável estabilidade in vitro (por meio de ensaios na presença de PBS, apo-transferrina e soro de sangue humano) e in vivo (pela análise de sangue e urina após administração em camundongos normais). O estudo de biodistribuição em camundongos demonstrou a captação principal nos intestinos e fígado, relacionando-se com a lipofilicidade (log P 1,40) do composto. Nas condições estudadas, não foi possível obter os radiocomplexos de 67Ga com as bis(tiossemicarbazonas) com rendimentos e pureza satisfatórios. No entanto, obteve-se o radiocomplexo de 111In com a bis(tiossemicarbazona), com grupos metila como substituintes no grupo N, com rendimento quantitativo e alta pureza, progredindo para os ensaios de estabilidade e biodistribuição. Sobre a estabilidade, o radiocomplexo de 111In com a bis(tiossemicarbazona) se mostrou menos estável que o complexo de 67Ga com a bis(semicarbazona), porém com similar comportamento na biodistribuição sendo captado, preferencialmente, no intestino (via de excreção) e no fígado (via metabólica). Ambos complexos são lipofílicos, no entanto, o 111In (log P 2,66) apresenta melhor saída da corrente sanguínea. Os novos radiocomplexos se mostraram promissores para estudos futuros buscando melhoria molecular (por questões de solubilidade, por exemplo) e especificidade via bioconjugação.
Title in English
GaIII and InIII radiocomplexes derived from the designed multidentate ligands aiming nuclear medicine applications
Keywords in English
gallium
imines
índium
radiocomplexes
semicarbazones
thiosemicarbazones
Abstract in English

In this thesis, a design of new Re, Ga and In coordination compounds is proposed. The ligands semicarbazones, thiosemicarbazones and imines could be prepared from 3-(chloromethyl)-2-hydroxy-5-methylbenzaldehyde as initial material. This aldehyde is not available commercially, but it could be obtained in three steps from 2,6-bis(hydroxymethyl)-4-methylphenol in 76 % yield. Using N-alkylation and condensation reactions, the ligands were prepared in 60 to 75 % yields. A series of tridentate, pentadentate and hexadentate ligands were designed to different metal ions, showing the versatility of the chloride/aldehyde reagent. Unfortunately, the ReV complexes were not fully characterized as stable complexes. Semi and thiosemicarbazones, H4bsc and H4btsc, formed GaIII and InIII complexes, as hexadentate ligands in good yields (60-90 %). The hexacoordinated bis(semicarbazone) Ga complex, [Ga(HbscPh)], was obtained as a zwitterion neutral compound and as a cationic form of a nitrate salt, from [Ga(acac)3] and [Ga(NO3)3], respectively. The same ligand, H4bscPh, reacted with [In(acac)3], resulting a zwitterion neutral In complex, [In(HbscPh)], but using [InCl3] a mixture of products was observed. The radioactive congener complex [67Ga(HbscPh)] was obtained in quantitative yields from 67GaCl3 (15 min, at room temperature) therefore the complex presented considerable stability in in vitro (PBS, apo-tranferrin, human blood serum assays) and in vivo (blood and urine after the administration to normal mice). The biodistribuition assays resulted in liver and instestines uptake, which could be related with the lipophilicity of the complex (log P 1,44). In experimental conditions, bis(thiossemicarbazones) 67Ga radiocomplexes were not obtained in reasonable yield and purity. However the radiocomplex [111In(HbtscMeMe)] was obtained in quantitative yields and in high purity (15 min, at room temperature), justifying stability assays. The 111In complex was less stable than 67Ga complex, though the similar uptake. The both complexes are lipophilic, but [111In(HbtscMeMe)] (log P 2,66) presented better blood clearance. The results were promising and new studies toward structural optimizing are proposed, in this way, water soluble complexes and specific agents (coupling to biomolecule) could be prepared.

 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-02-01
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.