• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.75.2012.tde-11042013-163756
Documento
Autor
Nombre completo
Sergio Pereira da Costa
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2012
Director
Tribunal
Olivares, Igor Renato Bertoni (Presidente)
Leite, Flávio
Souza, Gilberto Batista de
Título en portugués
Aplicação de ferramentas da qualidade no desenvolvimento de métodos multiresíduos
Palabras clave en portugués
multiresíduo
qualidade
validação
Resumen en portugués
O presente trabalho estuda a aplicação de ferramentas da qualidade em dois métodos multiresíduos, sendo utilizados como instrumento para desenvolvimento de novos métodos e otimização de métodos existentes. As ferramentas utilizadas foram o planejamento experimental, a validação de métodos e o cálculo de incerteza de medição, as quais foram aplicadas no método QuEChERS, já bem difundido na literatura, e no método RSE (Refrigerated Sorptive Extraction), técnica miniaturizada de extração. Foi aplicado planejamento experimental no método QuEChERS visando a otimização do processo de extração de organoclorados (14 no total, sendo 12 Organoclorados e 2 PCBs) em pescado, em que obteve-se valores de recuperação satisfatórios dentro da faixa de 70 a 120 % como é exigido pelo protocolo de validação SANCO 12495:2011. Neste processo foi otimizado as quantidades de sais de trabalho como NaCl, C18 e o PSA, fatores que interferem diretamente no resultado final de recuperação. A mesma ferramenta de planejamento experimental foi utilizada na otimização da fase de PDMS (fase extratora do sistema RSE desenvolvido) visando obter a melhor condição de trabalho, atuando com os fatores de temperatura e tempo de mufla, além do tempo de exposição ao meio ambiente para resfriamento entre a pré-cura e a pós-cura. O processo de validação e cálculo de incerteza de medição foi realizado para o método QuEChERS avaliando parâmetros primordiais para demonstrar que o método é adequado ao uso pretendido. Foi estudado o parâmetro linearidade, pelo coeficiente de determinação, resíduos e incerteza da curva, além da aplicação de metodologia de investigação na adequação da curva analítica linear, com testes como outlier, homoscedasticidade e modelo. Os dados apresentados foram satisfatórios, observando resultados dentro do que foi planejado, inexistência de outliers pela utilização do teste de Grubbs (foi encontrado valores perto do limite máximo do valor critico para os compostos ppE e ppD), teste de Cochran para análise de homoscedasticidade nos resíduos em torno da curva (todos se apresentaram homogêneos com o teste utilizado) e o teste de modelo com o teste de falta de ajuste, em que foi averiguado se o modelo linear é o mais adequado para metodologia. Além da linearidade, também foram avaliados os parâmetros seletividade, precisão (com CV abaixo dos 20%) e recuperação (valores entre 70 e 120%), fatores primordiais para o processo de validação, considerando que alguns destes também influenciam diretamente na incerteza do resultado final. Desta maneira foi possível avaliar a aplicabilidade do planejamento experimental no desenvolvimento de novos métodos de extração, como no caso do RSE, bem como na otimização de métodos já bem fundamentados, como no caso do método QuEChERS, se demonstrando como ferramenta primordial em ambos os casos. Quanto ao método QuEChERS, também foi possível avaliar a adequação do método quanto aos requisitos de validação e incerteza, os quais são essenciais para confiabilidade dos resultados analíticos.
Título en inglés
Application of quality tools in the multiresidue methods development
Palabras clave en inglés
multiresidue
quality
validation
Resumen en inglés
The paper studies the application of quality tools in two multiresidue methods, being used as a tool for developing and optimization methods. The tools used were the experimental design, method validation and measurement uncertainty, which were applied in the QuEChERS method, already widespread in the literature, and the RSE method (Refrigerated Sorptive Extraction), miniaturized extraction technique. Experimental design was applied in the QuEChERS method in order to optimize the extraction process of organochlorines (14 in total, 12 Organochlorines and 2 PCBs) in fish, which gave satisfactory recovery values within the range of 70 to 120% as is required by the validation protocol SANCO 12495:2011. This process was optimized the quantities of salts as NaCl, C18 and PSA, factors that directly affect the final outcome of recovery. The same experimental design tool was used in the optimization of extraction phase (PDMS extraction phase system developed to RSE) to obtain the best working condition, leading with the factors as time and temperature on the muffle, and the time of exposure to the environment to cooling between pre-cure and post-cure. The process of validation and measurement uncertainty was conducted to evaluate the method QuEChERS parameters to show that the method is suitable for the purpose. We studied the linearity parameter, the determination coefficient, residues and uncertainty of the linear curve, and the application of a methodology to observe the adequacy of the linear calibration curve, with testing as an outlier and homoscedasticity model. The data presented were satisfactory, no outliers was identified by the Grubbs test (values was found near the upper limit of the critical value for compounds PPE and PPD), Cochran test for analysis of homoscedasticity in the residue around the calibration curve (all performed with homogeneous assay) and the test model with the lack of fit test, where it was examined whether the linear model is the most appropriate for methodology. Besides linearity, were also evaluated parameters as selectivity, precision (CV below 20%) and recovery (values between 70 and 120%), important factors for the validation process, whereas some of these also has influenced of the final results of uncertainty. In this way it was possible to evaluate the applicability of the experimental design to develop new extraction methods, as in the case of RSE, and the optimization of the method QuEChERS demonstrating an important tool in both cases. For the QuEChERS method was also possible to assess the adequacy of the method for the requirements validation and uncertainty, which are essential for reliability of analytical results.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-04-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.