• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.75.2014.tde-10122014-105152
Document
Auteur
Nom complet
Fernanda Scavassa Ribeiro do Prado
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2014
Directeur
Jury
Mazo, Luiz Henrique (Président)
Cavalheiro, Eder Tadeu Gomes
Mascaro, Lucia Helena
Titre en portugais
Preparação, caracterização e testes de eletrodo modificado com filme de bismuto para aplicação na análise voltamétrica de metais pesados
Mots-clés en portugais
eletrodo de filme de bismuto
metais pesados
voltametria de onda quadrada de redissolução anódica
Resumé en portugais
Devido à alta toxicidade do mercúrio, os eletrodos contendo este metal vêm sendo substituídos por eletrodos modificados, dentre eles o filme de bismuto (f-Bi) tem demonstrado ser uma boa alternativa, pois apresentam comportamento e desempenho semelhante aos eletrodos de mercúrio, além de baixa toxicidade. A fim de se determinar os metais Cd2+ e Pb2+ em amostras de água do Rio Tietê, um eletrodo de f-Bi depositado de forma ex situ foi desenvolvido. As condições para a formação do f-Bi foram otimizadas e as melhores condições foram alcançadas utilizando uma solução de tampão acetato 0,2 mol L-1 pH 4,5 contendo 1,0x10-3 mol L-1 de Bi3+, aplicando um potencial de deposição de -0,50 V por 200 s. A determinação dos metais foi realizada através da voltametria de onda quadrada de redissolução anódica (SWASV - do inglês Square Wave Anodic Stripping Voltammetry), seus parâmetros foram otimizados e as melhores condições encontradas foram: frequência de 100 Hz; amplitude de pulso de 20 mV; step potential de 1 mV; potencial de pré-concentração de -0,925 V e tempo de pré- concentração de 450 s. Após a otimização dos parâmetros da SWASV foi construída uma curva analítica para os íons Cd2+ e Pb2+ na faixa de concentração de 5,0x10-8 a 3,0x10-6 mol L-1. As curvas analíticas apresentaram um aumento linear da corrente de pico em função da concentração dos metais com limite de detecção de 1,21 x10-7 e 1,13 x10-7 mol L-1 para o Cd e Pb, respectivamente. O método desenvolvido foi aplicado em amostras de água do rio Tietê e o f-Bi detectou Pb em concentração na ordem de 10-8 mol L-1.
Titre en anglais
Preparation, characterization and test for a modified bismuth film electrode for applying in voltammetric analysis heavy metals
Mots-clés en anglais
bismuth film electrode
heavy metals
square wave voltammetry anodic stripping voltammetry technique
Resumé en anglais
Since Mercury is highly toxic, electrodes made with metal have been replaced by modified electrodes, among with bismuth film electrodes (f-Bi), and these latter ones have shown to be a good alternative, because they present both behavior and performance similar to the mercury electrodes, along with low toxicity. In order to determine Cd2+ and Pb2+ in water samples from the Tietê River, an f-Bi electrode laid up ex situ was developed. The conditions for the f-Bi formation were optimized and the best conditions were reached by using a solution of 0,2 mol L-1 acetate buffer with pH 4,5 containing 1,0 x10-3 mol L-1 of Bi3+, applying a deposition potential of -0,50 V for 200 s. Determinations of the metals was done by the square wave voltammetry anodic stripping voltammetry technique (SWASV), its parameters were optimized and the best conditions found were: 100 Hz frequency; 20 mV pulse amplitude; 1 mV step potential; -0,925 V pre-concentration potential and 450 s pre-concentration time. After the optimization of the technique an analytical curve was built with the addition of Cd2+ e Pb2+ metals in the concentration range between 5,0 x10-8 and 3,0 x10-6 mol L-1. The analytical curves showed a linear increase for the peak current in function of the concentration of the metals with detection limit of 1,21 x10-7 e 1,13 x10-7 mol L-1 for Cd and Pb, respectively. The developed method was applied in water samples from the Tietê River and the f-Bi detected Pb in a concentration of 10-8 mol L-1 order.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-01-13
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.