• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.75.2015.tde-07102015-105005
Document
Auteur
Nom complet
Camila Domingues Mendonça
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2015
Directeur
Jury
Machado, Sergio Antonio Spinola (Président)
Pacces, Vítor Hugo Polisél
Banda, Giancarlo Richard Salazar
Titre en portugais
Determinação eletroanalítica e cromatográfica de Metilparabeno. Uma comparação estatística
Mots-clés en portugais
Comparação estatística
Cromatografia líquida
Eletroanalítica
Metilparabeno
Resumé en portugais

A cromatografia a líquido de alta eficiência e a voltametria de onda quadrada foram estudadas e comparadas estatisticamente para a detecção do contaminante emergente metilparabeno (MePa). Os parabenos vêm sendo amplamente utilizados como conservantes em cosméticos, alimentos e remédios. É crescente o número de estudos que visam à detecção dos parabenos em virtude dos males causados à saúde humana, devido às suas características de serem carcinogênicos e interferentes endócrinos. Para determinação cromatográfica, foi desenvolvido um método analítico que utilizou filtração à vácuo seguida de análise cromatográfica acoplada a um detector UV. O eletrodo de diamante dopado com boro (BDD) foi utilizado para determinação eletroanalítica de MePa pela técnica voltamétrica. Para a análise cromatográfica, foi observada boa linearidade (0,999) na faixa de 0,5 a 30 mgL-1, com limite de detecção e quantificação de 0,49 mgL-1 e 0,73 mgL-1, respectivamente, para amostra de água natural superficial e para a amostra de cosmético 1,26 mgL-1 e 1,88 mgL-1, respectivamente. A dependência da corrente pelo pH e os parâmetros eletroquímicos (frequência, amplitude e step) foram estudados para obtenção de condições experimentais ótimas na determinação de MePa. Foi observado que o eletrólito suporte ideal é o tampão PBS 0,1 molL-1 (pH 7,5). Linearidade adequada (0,998), na mesma faixa de trabalho, com limite de detecção e quantificação de 0,43 mgL-1 e 1,44 mgL-1, respectivamente, foram encontrados para a técnica voltamétrica. Os métodos utilizados em ambas as técnicas foram validados em uma amostra de água natural superficial, coletada em região pouco impactada, e em uma amostra de cosmético. Utilizando o método cromatográfico, foram obtidos intervalos de recuperação entre 95,6% e 101,6% com RSD inferior a 4,8% (n = 3) e entre 78,0% e 99,8% com RSD inferior a 2,2% (n = 3) para amostras de água natural superficial e de cosmético, respectivamente. Na determinação eletroanalítica, soluções fortificadas daquelas amostras mostraram intervalo de recuperação entre 92,6% e 106,4%, com um desvio-padrão relativo (RSD) inferior a 9,76% (n = 3), para amostra de água superficial natural, e entre 90,0% e 112,6% com RSD inferior a 7,4% (n = 3), para amostra de cosmético. Os resultados das detecções cromatográfica e eletroanalítica foram comparados e analisados estatisticamente segundo o método de Miller e Miller. Através do teste t de Student pareado, demonstrou-se que a metodologia eletroanalítica é capaz de determinar MePa com boa precisão tal como a técnica padrão de detecção, a cromatografia, na faixa de trabalho de 1,0 a 30 mgL-1.

Titre en anglais
Electroanalytical and chromatographic determination of Methylparaben. A statistical comparison
Mots-clés en anglais
Electroanalysis
Liquid chromatography
Methylparaben
Statistical comparison
Resumé en anglais

The high performance liquid chromatography and square wave voltammetry have been studied and compared statistically to detect the emerging contaminant methylparaben (MePa). Parabens have been widely used as preservatives in cosmetics, food and drugs. It is increasing the number of studies that aimed the detection of parabens because of its possible hazardous effect in the human health, as probably being carcinogenics and endocrine disruptors. For chromatographic determination, an analytical method that used vacuum filtration followed by chromatographic analysis coupled to a UV detector was developed. The boron doped diamond electrode (BDD) was used to electroanalytical determination to MePa by voltammetric technique. The chromatographic analysis showed good linearity (0.999) in the range from 0.5 to 30 mgL-1, with detection and quantification limit of 0.49 mgL-1 and 0.73 mgL-1, respectively, for natural surface water sample and to the cosmetic sample 1.26 mgL-1 and 1.88 mgL-1, respectively. The dependence of the current to pH and electrochemical parameters (frequency, amplitude and step) were studied to obtain the optimal experimental conditions in determining MePa. It has been observed that the ideal supporting electrolyte is PBS 0.1 molL-1 (pH 7.5). Adequate linearity (0.998), in the same working range, with detection and quantification limit of 0.43 mgL-1 and 1.44 mgL-1, respectively, were found for the voltammetric technique. The methods used in both techniques were validated in a sample of natural surface water, collected in little impacted region, and a cosmetic sample. Using the chromatographic method were obtained recovery intervals between 95.6% and 101.6% with RSD less than 4.8% (n = 3) and between 78.0% and 99.8% with RSD less than 2.2% (n = 3) for samples of natural surface water and cosmetic, respectively. In electroanalytic determination, fortified solutions of those samples showed a recovery range between 92.6% and 106.4% with a relative standard deviation (RSD) less than 9.76% (n = 3) for natural surface water sample and between 90.0% and 112.6% with RSD less than 7.4% (n = 3), for cosmetic sample. The results of chromatographic and electroanalytical detections were compared and statistically analyzed by the Miller and Miller's method. Using the Student's paired t-test, it was demonstrated that electroanalytical methodology is able to determine MePa with good accuracy as standard detection technique, chromatography, on working range of 1.0 to 30 mgL-1.

 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-10-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.