• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.75.2018.tde-05072018-100643
Documento
Autor
Nombre completo
Bruna Ferreira Gomes Lobo
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2018
Director
Tribunal
Colnago, Luiz Alberto (Presidente)
Oliveira, Caue Ribeiro de
Tosin, Giancarlo
Mazo, Luiz Henrique
Ribeiro, Tatiana Santana
Título en portugués
Estudo da magnetoeletrólise durante o acoplamento RMN-Eletroquímica in situ
Palabras clave en portugués
acoplamento RMN-eletroquímica
células eletroquímicas miniaturizadas
magnetoeletrólise
Resumen en portugués

Recentemente foi demonstrado que a técnica de ressonância magnética nuclear no domínio do tempo (RMN-DT) é uma importante ferramenta analítica que é passível de ser acoplada com a eletroquímica (EQ-RMN). No entanto, como foi demonstrado nesse presente trabalho, a técnica de RMN não é passiva, ou seja, ela atua sobre as reações eletroquímicas aumentando a velocidade das reações realizadas in situ quando essas são limitadas por transporte de massas e/ou transferência de cargas. Essa alteração da taxa de reação é ocasionada por um fenômeno conhecido por magnetoeletrólise, que tem como principal resultante a força de Lorentz, que é o produto vetorial entre o campo magnético e o fluxo de íons gerado durante a eletrólise. O efeito do campo magnético sobre diferentes sistemas eletroquímicos foi comprovado na presença de campo magnético de equipamentos de RMN de baixa e alta resolução. Além do foco dado para a magnetoeletrólise durante o acoplamento EQ-RMN, novas células eletroquímicas foram miniaturizadas para a utilização com a RMN a partir de um método simples, rápido e robusto. Também foram feitas medições de velocimetria utilizando a técnica de imagem por spin eco com as quais foi possível visualizar e quantificar o efeito do campo magnético atuando sobre a reação de eletrodeposição de cobre realizada in situ. Esse trabalho foi o primeiro a utilizar o campo magnético do espectrômetro de RMN para estudar a magnetoeletrólise. Além disso, esse trabalho de doutorado foi o primeiro a utilizar um espectrômetro de RMN de bancada de alta resolução para o acoplamento com a eletroquímica.

Título en inglés
Magnetoelectrolysis study during the NMR-Electrochemistry in situ coupling
Palabras clave en inglés
magnetoelectrolysis
miniaturized electrochemical cell
NMR-electrochemistry coupling
Resumen en inglés

Recently it was demonstrated that time domain Magnetic Nuclear Resonance (TD-NMR) is an important analytical technique which can be coupled to electrochemistry (EC-NMR). However, it was demonstrated in this work that NMR is not a passive technique, in other words it affects the electrochemical reactions performed in situ by increasing the reaction rate of mass transport and/or charge transfer limited reactions. This change in the reaction rate is caused by a phenomenon known as magnetoeletrolysis, it has as main resultant the Lorentz force, which is the vectorial product between the magnetic field vector and the ion flow produced during the electrolysis. The magnetic field effect on different electrochemical systems has been shown in the presence of magnetic fields of low and high resolution NMR spectrometers. In addition to the focus given to magnetoelectrolysis during the EC-NMR coupling, novel electrochemical cells were miniaturized for coupling with NMR by using a simple, rapid and robust method. Velocimetry measurements were also made using the spin-echo imaging technique with which it was possible to visualize and quantify the effect of the magnetic field acting on the in situ copper electrodeposition reaction. This work was the first to use the magnetic field of the NMR spectrometer to study magnetoelectrolysis. In addition, this doctoral thesis was the first to use a bench-top high resolution NMR spectrometer for coupling with electrochemistry.

 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-07-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.