• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.75.2014.tde-04052015-153440
Document
Author
Full name
Ricardo Tomitan Kushikawa
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2014
Supervisor
Committee
Teixeira, Marcos Fernando de Souza (President)
Varanda, Laudemir Carlos
Yamanaka, Hideko
Title in Portuguese
Aplicação de nanopartículas intermetálicas de NiSb e metálicas de Pt suportadas em carbono Vulcan® XC72 no desenvolvimento de um sensor eletroquímico
Keywords in Portuguese
nanopartícula metálica
Sensor eletroquímico
tetraciclina
Abstract in Portuguese
Neste trabalho desenvolveu-se um sensor eletroquímico a partir da modificação de superfície de um eletrodo de carbono vítreo com nanopartículas metálicas de Pt e intermetálicas de NiSb suportadas em carbono Vulcan® XC72. Tal modificação visou à obtenção de um sensor de baixo custo, simples e rápido para determinação do cloridrato de tetraciclina (TTC). A tetraciclina é um fármaco com propriedades antibióticas amplamente utilizado na saúde humana e animal devido sua baixa toxicidade e fácil obtenção. A modificação de superfície do eletrodo de trabalho foi realizada a partir da adição de uma suspensão das nanopartículas em dimetilformamida (DMF) (1 mg/1 mL) sobre a superfície do eletrodo previamente limpo e os estudos voltamétricos conduzidos utilizando as técnicas de voltametria cíclica, voltametria de pulso diferencial e cronoamperometria. Como consequência dos resultados obtidos, prosseguiu-se apenas com os estudos da nanopartícula de Pt na construção de um sensor para determinação da TTC. As nanopartículas apresentam propriedades diferentes daquelas exibidas pelo mesmo material quando estes se encontram em partículas de maior tamanho como bulks, e dentre suas principais características, o aumento da área superficial provocado pela modificação do eletrodo mostrou resultados promissores na detecção e quantificação do analito. Após diversos estudos sobre o eletrólito de suporte e o pH, obteve-se a melhor resposta voltamétrica em solução de tampão fosfato 0,10 mol L-1 pH 3,0 através da voltametria cíclica tanto na determinação do analito em água purificada quanto na determinação em urina sintética. O eletrodo modificado com nanopartículas de Pt apresentou resposta linear na faixa de 9,99 e 44,01 µmol L-1, limite de detecção 4,28 µmol L-1 e limite de quantificação 14,26 µmol L-1. A aplicação do eletrodo em uma amostra de urina sintética ocorreu com sucesso, alcançando um valor de concentração com diferença de 3% para o valor real.
Title in English
Application of Vulcan® XC72 carbon-supported NiSb intermetallic nanoparticles and Pt metallic particles for the development of an electrochemical sensor
Keywords in English
Electrochemical sensor
metallic nanoparticle
tetracycline
Abstract in English
In this work it was developed an electrochemical sensor by the surface modification of a glassy carbon electrode with metallic Pt nanoparticles and intermetallic NiSb nanoparticles in Vulcan® XC72 carbon as the support. Such surface modification sought to obtain a low cost sensor, easy to work and quick working to determine tetracycline hydrochloride. The tetracycline is a drug with antibiotics properties widely used in human and animal treatment due to its low toxicity and easy obtainability. The surface modification of the work electrode was accomplished through the addition of a suspension of the nanoparticles in dimethylformamide (1 mg/1 mL) in the electrode surface previously cleaned and the voltammetric studies conducted with the use of techniques such as cyclic voltammetry, differential pulse voltammetry and chronoamperometry. As a consequence of the obtained results, only the studies with the sensor developed with Pt nanoparticles were continued for the tetracycline determination. The nanoparticles presents different properties of those shown by the same material when these are in bigger forms, such as bulks and among the main characteristic, the superficial area increase caused by the electrode modification shown promising results for the detection and quantification of the analyte. After several studies about the supporting electrolyte and the pH, it was obtained a better voltammetric response in phosphate buffer solution 0.1 mol L-1 and pH 3.0 for the determination of the analyte in purified water and synthetic urine. The modified electrode with metallic Pt nanoparticles had a linear response in the range 9.99 to 44.01 µmol L-1 with a detection limit of 4.28 µmol L-1 and quantification limit of 14.26 µmol L-1. The electrode application in a synthetic urine sample was a success, reaching concentration values with a difference within 3% of the real value.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-05-15
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.