Disertación de Maestría
DOI
https://doi.org/10.11606/D.75.2015.tde-09092015-151027
Documento
Autor
Nombre completo
Tatiana Monaretto
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2015
Director
Tribunal
Colnago, Luiz Alberto (Presidente)
Imasato, Hidetake
Pereira, Fabiola Manhas Verbi
Título en portugués
Desenvolvimento e aplicação de sequências de pulsos CWFP com alternância de fase em RMN no domínio do tempo
Palabras clave en portugués
alternância de fase
CP-CWFP
CWFP
RMN baixo campo
SSFP
Resumen en portugués
Os tempos de relaxação longitudinal (T1) e transversal (T2) têm sido frequentemente utilizados na RMN no domínio tempo (RMN-DT) para a obtenção de propriedades físicas e químicas de alimentos, polímeros, petróleo e produtos farmacêuticos. A sequência de pulsos Carr-Purcell- Meiboom-Gill (CPMG) é o método tradicional e mais utilizado para medida de T2, por ser uma técnica rápida para determinação deste tempo de relaxação. Por outro lado, a determinação do T1 não é muito comum, pois as técnicas tradicionalmente utilizadas para sua mensuração, Inversão Recuperação (IR) e Saturação Progressiva (SP), requerem longo tempo de análise. Desta forma, vários autores vêm desenvolvendo métodos bidimensionais (2D) rápidos, para medida de ambos os tempos de relaxação ou da razão T1/T2. Entretanto, estes métodos requerem sequências de pulsos e tratamentos de dados mais sofisticados do que os métodos unidimensionais (1D). Recentemente têm sido desenvolvidas técnicas 1D rápidas para determinação simultânea de T1 e T2 no estado estacionário de precessão livre (Steady State Free Precession - SSFP). Estas sequências são denominadas de Continuous Wave Free Precession (CWFP) e Carr-Purcell Continuos Wave Free Precession (CP-CWFP). A desvantagem desses métodos, é que estes necessitam o ajuste da frequência de offset e do tempo entre os pulsos (Tp), a fim de se obter um ângulo de precessão múltiplo ímpar de π. Desta forma, neste estudo foi proposta a utilização de técnicas provenientes da CWFP com alternância de fase (AF) de π entre os pulsos, as quais na condição de ressonância são independentes do Tp, para Tp<T2∗. Estas sequências são a CWFPx-x e CP-CWFPx-x, que se diferem da CWFP e CP-CWFP somente pela AF de π entre os pulsos de refocalização (x' e -x') e a CPMG90y-y que é similar a CPMG90, porém, os pulsos de refocalização são com alternância de fase (y e -y). Nestas sequências, os tempos de relaxação são determinados através da amplitude do sinal logo após o primeiro pulso, |M0|, a amplitude do sinal no estado estacionário, |MEE|, e a constante de tempo exponencial T∗. As constantes de tempo T1 e T2 obtidas com as sequências com AF de π foram iguais ou muito similares às obtidas pelos métodos padrão de determinação destas constantes de tempo (IR e CPMG). Entretanto, dentre as sequências com e sem AF de π apresentadas neste estudo, a CP-CWFPx-x demonstrou ser a melhor sequência para determinação de T1 e T2. Já que o sinal desta apresenta elevada faixa dinâmica do estado quase-estacionário ao estado estacionário que permite a determinação dos tempos de relaxação em amostras com qualquer razão T1/T2. Ainda, esta característica da CP-CWFPx-x possibilita sua aplicação em casos onde há baixa razão sinal ruído.
Título en inglés
Development and Applications of CWFP Pulses Sequences with Phase Alternation in Time Domain NMR
Palabras clave en inglés
CP-CWFP
CWFP
NMR low field
phase alternantion
Resumen en inglés
Longitudinal (T1) and transverse (T2) relation times have been often used in time domain NMR (TD-NMR) to obtain physical and chemical properties of the food, polymers, petroleum and pharmaceutical materials. The Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence is the standard method to measure T2 because it is a fast and accurate method. On the other hand, pulse sequences for T1 determination, as Inversion Recovery (IR) e Saturation Progressive (SP), is not common, such require long time. Under these circumstances, several authors developed two-dimensional (2D) fast methods to determine relation times and/or T1/T2 ratio. However, these methods require pulse sequences that are more sophisticated and difficult data processing than one-dimensional (1D) method. This way, recently, fast 1D techniques, based on Steady State Free Precession (SSFP), has been developed to determine simultaneous T1 and T2.These methods are named the Continuous Wave Free Precession (CWFP) and Carr-Purcell Continuos Wave Free Precession (CP-CWFP). The main disadvantage of these methods is that they require the adjustment of the offset frequency and the time between pulses (Tp) in order to obtain a precession angle odd multiple of π. Therefore, in this study, it proposed to use CWFP technique with π phase alternation (PA), which in resonance are Tp independent, when Tp<T2∗. These pulse sequences were named CWFPx-x, CP-CWFPx-x. They are similar to CWFP and CP-CWFP, however with π PA between refocusing pulse (x' and -x'). In addition, other pulse sequence, named CPMG90y-y will be analyzed. It is similar to CPMG90, however, the refocusing pulses have PA (y' and -y'). In these pulse sequences, the relaxation times are determine by the signal amplitude immediately after the first pulse |M0| and in the stationary state |Mss|, as wells as the exponential time constant T∗. T1 and T2 determine by the π PA sequences were similar those one obtained by standard methods, IR and CPMG. Nevertheless, among the sequences with or without PA, show in this study, the CP-CWFPx-x proved be the best sequence for T1 and T2 determination, because of its highest dynamic range of the quasi-stationary state to stationary state. Thus, it provides the relaxation times determination independent of the T1/T2 ratio and can be use in cases of the low-reason signal to noise ratio.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-09-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.