• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.75.2015.tde-09092015-144743
Documento
Autor
Nome completo
Rodrigo Henrique dos Santos Garcia
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2015
Orientador
Banca examinadora
Colnago, Luiz Alberto (Presidente)
Tannus, Alberto
Tormena, Cláudio Francisco
Título em português
Desenvolvimento de pulsos formatados para redução do tempo morto de espectrômetros de RMN no domínio do tempo
Palavras-chave em português
cinética do araldite por RMN-DT
Pulso formatado
Ressonância Magnética Nuclear
RMN de baixo campo
tempo morto
Resumo em português

A ressonância magnética nuclear no domínio do tempo (RMN-DT), possui inúmeras vantagens em relação à RMN de alta resolução tais como: baixo custo do equipamento, de análise e manutenção e não precisa de operador especializado. Apesar disso a técnica de RMN-DT ainda tem um campo muito grande de desenvolvimento para análise de componente com baixa mobilidade molecular como sólidos amorfos e cristalinos. Isto requer o desenvolvimento de instrumentação e/ou métodos de análise que se consiga medir o sinal de RMN em menos de 10 µs, após a irradiação da amostra. O tempo entre o final da excitação e o começo da aquisição do sinal é conhecido como tempo morto. A opção estudada nesta dissertação para redução do tempo morto foi o uso de pulsos formatados, que já são utilizados em experimentos de RMN em alta resolução e de imagens por RMN, para excitação seletiva. No entanto, pulsos formatados não têm sido utilizados em RMN-DT. A principal vantagem desses pulsos é que eles são projetados para que a potência no final do pulso seja mínima, o que diminui o tempo morto do espectrômetro. No caso do pulso convencional, na forma retangular, a potência no final do pulso é máxima, o que aumenta o tempo morto. Os pulsos formatados utilizados foram pulsos Sinc, Sine e também pulsos com início similar aos pulsos retangulares, com potência máxima, e que depois de certo tempo tem decaimento similar aos pulsos Sinc e Sine. Esses pulsos inéditos foram denominados Reta-Sine e Reta-Sinc. Foram avaliados amostras heterogêneas (solido-líquido) e sólidas como CaSO4.2H2O, farelo de soja, polímeros amido e Policaprolactona. Esses pulsos também foram usados para monitorar reações de polimerização da resina epóxi com poliamida (Araldite®). Com esses métodos foi possível reduzir o tempo morto de espectrômetro de 23MHz 23 µs para 14 µs e de 20 Mhz de 9 para 6 µs. Com isso conclui-se que o pulsos formatados podem reduzir significativamente o tempo morto de espectrômetro de RMN-DT, sem acessórios ou custo financeiro, pois as sequências podem ser instalada e usadas em qualquer espectrômetro moderno.

Título em inglês
Development formatted pulses to reduce the dead time of spectrometers in in Time Domain NMR
Palavras-chave em inglês
DEAD TIME
FORMATTED PULSE
NMR
NMR low field
Resumo em inglês
The nuclear magnetic resonance in the time domain (TD-NMR) It has numerous advantages over the high-resolution NMR such as low cost of equipment, analysis and maintenance and requires no specialized operator. Nevertheless NMR DT technique also has a very large development field for component analysis with a low molecular mobility as amorphous and crystalline solids. This requires the development of instrumentation and / or analysis methods that can measure the NMR signal in less than 10 µs, after irradiation of the sample. The time between the end of excitation and signal acquisition the beginning is known as dead time. The option studied in this work to reduce the dead time was the use of formatted pulses, which are already used in NMR experiments in high resolution and NMR imaging for selective excitation. However, formatted pulses have not been used in NMR DT. The main advantage of these pulses is that they are designed so that the power in the pulse end is minimized, which reduces the dead time of the spectrometer. In the case of conventional pulse in rectangular form, the power in the pulse end is maximum, which increases the dead time. Formatted pulses used were Sync pulses, Sine and also pulses beginning similar to rectangular pulses with maximum power, and after a while has similar decay to Sync and Sine wrists. These unpublished wrists were called Sine and Straight-Line-Sync. They were evaluated heterogeneous samples (solid-liquid) and solid as CaSO4.2H2O, soybean meal, starch polymers and Polycaprolactone. These pulses are also used to monitor polymerization reactions the polyamide epoxy resin (Araldite®). With these sequences it was possible to reduce the dead time of 23 µs 23MHz spectrometer to 14 µs e 20 Mhz from 9 to 6 µs. With this it is concluded that the formatted pulses can significantly reduce the dead time DT-NMR spectrometer, without fittings or financial cost because the sequences can be installed and used in any modern spectrometer.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2015-09-09
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.