• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.75.2009.tde-21122009-142446
Documento
Autor
Nome completo
Fabiano Okumura
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2009
Orientador
Banca examinadora
Mazo, Luiz Henrique (Presidente)
Andrade, Adalgisa Rodrigues de
Crespilho, Frank Nelson
Faria, Ronaldo Censi
Rezende, Maria Olimpia de Oliveira
Título em português
Estudo voltamétrico e desenvolvimento de metodologia eletroanalítica para determinação do inseticida fipronil utilizando o eletrodo compósito de grafite-poliuretana
Palavras-chave em português
Eletrodo compósito de grafite-poliuretana
Fipronil
Voltametria
Resumo em português
O comportamento eletroquímico do inseticida fipronil, 5-amino-[(2,6-dicloro)-4-trifluormetil-fenil]-4-trifluormetil-sulfinil-1H pirazol-3-carbonitrila, foi investigado pelas técnicas de voltametria cíclica, voltametria de onda quadrada, eletrólise a potencial controlado e voltametria de redissolução de onda quadrada utilizando o eletrodo compósito de grafite-poliuretana. O fipronil apresentou um comportamento de um sistema irreversível com potencial de pico de 0,95 V. O processo de transferência de carga apresentou um controle misto de difusão e adsorção de espécies na superfície do eletrodo. O pH 8,0 foi escolhido para o desenvolvimento de uma metodologia eletroanalítica para determinação do composto. Os estudos por eletrólise a potencial controlado mostraram que a oxidação do inseticida envolve a participação de um elétron. Na voltametria de onda quadrada, o melhor sinal de corrente foi obtido com os valores de freqüência de 100 s-1, amplitude de 50 mV e incremento de varredura de 2 mV. Os limites de detecção e de quantificação foram calculados pelo método da IUPAC e pelo método de extrapolação da curva analítica. A metodologia desenvolvida foi comparada com o método oficial de análise, a cromatografia líquida de alta eficiência com detecção de ultravioleta por meio do método de curvas de calibração por meio de adição externa de padrão e foi observada concordância entre os dois métodos no intervalo de concentração estudado. Nos estudos de pré-concentração, as melhores condições encontradas foram um potencial de acumulação de 0,5 V e tempo de acumulação de 120 s. Amostras de águas naturais, formulação veterinária e leite foram analisadas pelos procedimentos propostos.
Título em inglês
Voltammetric investigation and development of electroanalytical procedure for the determination of fipronil using the graphite-polyurethane composite electrode
Palavras-chave em inglês
Fipronil
Graphite-polyurethane composite electrode
Voltammetry
Resumo em inglês
The electrochemical behavior of the insecticide fipronil, 5-amine-[(2,6-dichloro)-4-trifluoromethyl-phenyl]-4-trifluoromethyl-sulfynil-1H pyrazole-3-carbonitrile, was investigated by cyclic voltammetry, square wave voltammetry, controlled potential electrolysis and square wave stripping voltammetry using the graphite-polyurethane composite electrode. The electrochemical behavior of fipronil is a typical irreversible system and a peak potential at 0.95 V was observed. The charge transference process is controlled by diffusion and adsorption of species at electrode surface. The pH value 8.0 was chosen in order to develop an electroanalytical methodology for the determination the compound. Controlled potential electrolysis studies showed that the fipronil oxidation involves the participation of one electron. Square wave voltammetry investigations showed that the best current intensity was obtained using the values of a frequency of 100 s-1, pulse amplitude of 50 mV and scan increment of 2 mV. The limits of detection and quantification were calculated the IUPAC equations and statistics equations. The developed methodology was compared to the official analysis method, high performance liquid chromatography with ultraviolet detection, using the calibration curves method. Both procedures are in agreement with the concentration-studied range. Stripping analysis studies were done in order to determine fipronil traces in natural water. The best conditions found were the accumulation potential of 0.5 V and accumulation time of 120 s. The electroanalytical methodology, based on the square wave voltammetry, was applied for the analysis of natural water samples, a commercial veterinary formulation and milk samples.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
FabianoOkumuraR.pdf (1.12 Mbytes)
Data de Publicação
2010-06-29
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.