Title in Portuguese
Estudo voltamétrico e desenvolvimento de metodologia eletroanalítica para determinação do inseticida fipronil utilizando o eletrodo compósito de grafite-poliuretana
Keywords in Portuguese
Eletrodo compósito de grafite-poliuretana
Fipronil
Voltametria
Abstract in Portuguese
O comportamento eletroquímico do inseticida fipronil, 5-amino-[(2,6-dicloro)-4-trifluormetil-fenil]-4-trifluormetil-sulfinil-1H pirazol-3-carbonitrila, foi investigado pelas técnicas de voltametria cíclica, voltametria de onda quadrada, eletrólise a potencial controlado e voltametria de redissolução de onda quadrada utilizando o eletrodo compósito de grafite-poliuretana. O fipronil apresentou um comportamento de um sistema irreversível com potencial de pico de 0,95 V. O processo de transferência de carga apresentou um controle misto de difusão e adsorção de espécies na superfície do eletrodo. O pH 8,0 foi escolhido para o desenvolvimento de uma metodologia eletroanalítica para determinação do composto. Os estudos por eletrólise a potencial controlado mostraram que a oxidação do inseticida envolve a participação de um elétron. Na voltametria de onda quadrada, o melhor sinal de corrente foi obtido com os valores de freqüência de 100 s-1, amplitude de 50 mV e incremento de varredura de 2 mV. Os limites de detecção e de quantificação foram calculados pelo método da IUPAC e pelo método de extrapolação da curva analítica. A metodologia desenvolvida foi comparada com o método oficial de análise, a cromatografia líquida de alta eficiência com detecção de ultravioleta por meio do método de curvas de calibração por meio de adição externa de padrão e foi observada concordância entre os dois métodos no intervalo de concentração estudado. Nos estudos de pré-concentração, as melhores condições encontradas foram um potencial de acumulação de 0,5 V e tempo de acumulação de 120 s. Amostras de águas naturais, formulação veterinária e leite foram analisadas pelos procedimentos propostos.
Title in English
Voltammetric investigation and development of electroanalytical procedure for the determination of fipronil using the graphite-polyurethane composite electrode
Keywords in English
Fipronil
Graphite-polyurethane composite electrode
Voltammetry
Abstract in English
The electrochemical behavior of the insecticide fipronil, 5-amine-[(2,6-dichloro)-4-trifluoromethyl-phenyl]-4-trifluoromethyl-sulfynil-1H pyrazole-3-carbonitrile, was investigated by cyclic voltammetry, square wave voltammetry, controlled potential electrolysis and square wave stripping voltammetry using the graphite-polyurethane composite electrode. The electrochemical behavior of fipronil is a typical irreversible system and a peak potential at 0.95 V was observed. The charge transference process is controlled by diffusion and adsorption of species at electrode surface. The pH value 8.0 was chosen in order to develop an electroanalytical methodology for the determination the compound. Controlled potential electrolysis studies showed that the fipronil oxidation involves the participation of one electron. Square wave voltammetry investigations showed that the best current intensity was obtained using the values of a frequency of 100 s-1, pulse amplitude of 50 mV and scan increment of 2 mV. The limits of detection and quantification were calculated the IUPAC equations and statistics equations. The developed methodology was compared to the official analysis method, high performance liquid chromatography with ultraviolet detection, using the calibration curves method. Both procedures are in agreement with the concentration-studied range. Stripping analysis studies were done in order to determine fipronil traces in natural water. The best conditions found were the accumulation potential of 0.5 V and accumulation time of 120 s. The electroanalytical methodology, based on the square wave voltammetry, was applied for the analysis of natural water samples, a commercial veterinary formulation and milk samples.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
FabianoOkumuraR.pdf (1.12 Mbytes)
Publishing Date
2010-06-29
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.