Nom complet
Rejane Mara Frizzarin
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2008
Directeur
Jury
Reis, Boaventura Freire dos (Président)
Chierice, Gilberto Orivaldo
Oliveira, Pedro Vitoriano de
Titre en portugais
Determinação espectrofotométrica de selênio em rações para animais empregando análise por injeção em fluxo
Mots-clés en portugais
Espectrofotometria
FIA
Multicomutação
Ração animal
Selênio
Resumé en portugais
Na presente dissertação foi desenvolvido um procedimento automático para a determinação de selênio em rações para animais doméstico digeridas em meio ácido. O método automatizado foi baseado no efeito catalítico do selênio(IV) na reação de sulfato de ferro amoniacal com EDTA em meio contendo NaNO3. O módulo de análise foi baseado no processo de multicomutação em fluxo. Tendo em vista que reação tem cinética lenta, o módulo de análise foi projetado com seis bobinas de reação acopladas em paralelo para permitir tempo de residência da zona de amostra em torno de cinco minutos, sem comprometer a freqüência de amostragem. Após a definição das variáveis de controle, amostras de rações para animais digeridas em meio de ácido nítrico/perclórico foram processadas. Os resultados referentes ao testes de adição de padrão apresentaram recuperação entre 95 e 109 %. Outras características importantes tais como desvio padrão relativo em torno de 2% (n = 8) e freqüência de amostragem de 60 determinações por hora foram observadas.
Titre en anglais
Spectrophotometric determination of selenium in ration for domestic animals employing flow injection analysis
Mots-clés en anglais
FIA
ration
selenium
spectrophotometry
Resumé en anglais
In this work it was developed an automatic procedure for the determination of selenium in ration for domestic animals digested in acidic medium. The automated method was based on the catalytic effect caused by selenium (IV) on the reaction of ammoniacal iron sulfate with EDTA in medium containing NaNO3. The analytical module was based on multicommuted flow process. Considering that the kinetic of reaction was slow, the analytical module was designed with six reaction coupled in parallel in order to allow that residence time of sample zone was increased up to 5 min without decrease of the analytical throughput. After definition of the system control variables, sample of animal ration mineralized in nitric/perchloric acid medium were processed. The results concerning to standard solution addition assays gave recoveries between the range of 95 % up to 109 %. Other profitable features such as a relative standard deviation of 2 % (n = 8) and an analytical throughput of 60 samples determination per hours were also achieved.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
RejaneMaraFrizzarinR.pdf (773.85 Kbytes)
Date de Publication
2012-11-05
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.