Avaliação de processos oxidativos para o tratamento ambientalmente adequado de fluidos de corte
Palavras-chave em português
fluidos de corte
processo Fenton
processo foto-Fenton
processos oxidativos avançados
Resumo em português
Durante o processo metalúrgico de usinagem de uma peça ocorre a geração de calor proveniente do atrito ferramenta/peça e cavaco/ferramenta. Para que ocorra uma menor geração de calor possibilitando o manuseio, bem como a minimização na deformação da peça, utilizam-se fluidos, que são soluções lubrificantes à base de óleos, água ou polímeros, podendo ser sintéticos ou não, diminuindo, assim, o coeficiente de atrito reduzindo-se a quantidade de calor gerado no processo. Há uma grande variedade de fluidos de corte disponíveis no mercado que são constituídos por diversos compostos como: aminas, compostos clorados e/ou aromáticos, glicóis, nitrosaminas além da presença de metais provenientes do processo de manufatura, portanto, sem tratamento, não podem ser lançados na rede de esgoto convencional. Atualmente não há um método de tratamento para os fluidos de corte nas indústrias. Nesse contexto, propõe-se um estudo sobre a viabilidade dos tipos de tratamento dos fluidos de corte para uma disposição adequada. Os processos de tratamento propostos neste trabalho compreendem hidrolise ácida e Processo Oxidativo Avançado (POA), mais especificamente, Sistema Fenton, além de propor um tratamento baseado na fotodegradação. A caracterização do fluido antes e após seu tratamento foi realizada por técnicas analíticas e espectrométricas. Os processos oxidativos mostraram-se satisfatórios para o tratamento dos efluentes, reduzindo os níveis de contaminantes aos permitidos pela legislação. O processo foto-Fenton mostrou-se mais eficiente que o processo Fenton na degradação de todos os parâmetros avaliados, incluindo BTEX e HPAs. Os processos de hidrólise ácida não apresentaram resultados satisfatórios, reduzindo apenas os metais aos níveis permitidos para descarte.
Título em inglês
Evaluation of oxidative processes for the environmentally apropriate treatment of cutting fluids
Palavras-chave em inglês
advanced oxidative processes
cutting fluids
Fenton process
photo-Fenton process
Resumo em inglês
During the cutting process, part of the heat generation results from tool-part and chip-tool friction. So that it happens a smaller generation of heat making possible the handling, as well as minimization in the tool deformation, cutting fluids are used, that are the oils base, water or polymeric lubricating solutions, could be synthetic or no, decreasing the attrition coefficient being reduced the amount of heat generated in the process. There is a great variety of cutting fluids that are constituted for several composed as: amines, chlorinated and/or aromatic composed, glycols and nitrosamines besides the presence of metals proceeding of manufacture process, therefore, without a treatment, they cannot be discarded in the conventional sewerage system. At the moment there isn't a treatment method for the cut fluids in the industries. In that context, intends a study about the viability types of cutting fluids treatment for appropriate disposition. Treatment processes proposed in this work understand acid hydrolysis and Advanced Oxidative Process (AOP), more specifically, Fenton System, in addition proposing a treatment based on the photodegradation (photo-Fenton process). The characterization of fluid before and after treatment it was accomplished by analytical and spectrometry techniques. Oxidative processes were exposed satisfactory for cutting fluids treatment, reducing the levels of pollutants to the allowed by the legislation. Photo-Fenton process was shown more efficient than Fenton process in the oxidation of BTEX and PAHs. Acid hydrolysis processes didn't present satisfactory results, just reducing the metals at the levels allowed for discard.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2008-09-02
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.