Título en portugués
Estudo estatístico do desempenho analítico das técnicas eletroquímicas VPD, VOQ e MVOQ para a redução do herbicida paraquat em UME-Au e sua quantificação em águas puras e naturais
Palabras clave en portugués
águas naturais
estatística
paraquat
técnicas eletroquímicas
Resumen en portugués
Neste trabalho foi realizado um estudo estatístico do desempenho analítico das técnicas eletroquímicas Voltametria de pulso diferencial (VPD), Voltametria de onda quadrada (VOQ) e Voltametria de múltiplas ondas quadradas (VMOQ) para a redução do herbicida paraquat em ultramicroeletrodo de ouro (UME-Au) e sua análise e quantificação em águas puras e naturais. Os estudos da redução eletroquímica do paraquat foram realizados em eletrólito de suporte Na2SO4 0,1 mol L-1 em pH = 5,5. Os resultados mostraram a presença de dois picos de redução bem definidos , com o pico 1 em -0,64 V e o pico 2 em -0,94 V vs Ag/AgCl 3,0 mol L-1. Para as análises foi utilizado o pico 1 que é referente a uma reação em solução, onde a superfície eletródica serve apenas como intermediadora na transferência eletrônica. Utilizando-se os parâmetros experimentais e voltamétricos otimizados, curvas de trabalho foram construídas em eletrólito de suporte preparado com água ultrapurificada. Para a VPD, VOQ e VMOQ, os limites de detecção encontrados utilizando-se o método descrito em Miller & Miller e considerando-se o pico 1 foram: 55,35 ± 0,18 µg L-1 , 37,50 ± 0,32 µg L-1 e 21,42 ± 0,51 µg L-1, respectivamente. A metodologia foi aplicada em amostras de águas coletadas no Rio Mogi-Guaçu na cidade de São Carlos-SP. A variação da inclinação das curvas de trabalho obtida nas análises destas amostras foi praticamente insignificante em relação àquela obtida utilizando-se o eletrólito de suporte preparado com água ultrapurificada para as três técnicas utilizadas, mostrando pouca interferência da matéria orgânica presente nas amostras de águas naturais. Os menores valores de concentração mensuráveis de paraquat nas amostras de águas naturais foram inferiores ao valor máximo de resíduos permitido pela legislação brasileira para águas residuárias (100 µg L-1), mostrando a viabilidade na aplicação da metodologia proposta. Os cálculos dos limites de detecção e quantificação, a avaliação dos erros experimentais e os limites de confiança foram realizados a partir do procedimento estatístico descrito em Miller & Miller. Os valores de limites de detecção encontrados apresentam um significado físico e realístico para esta grandeza, já que foram determinados por interpolação nas curvas analíticas, construídas a partir da relação entre as concentrações do pesticida e os sinais obtidos. Estes mesmos limites foram calculados utilizando-se o método recomendado pela IUPAC e os valores encontrados foram 29,43 µg L-1 para VPD, 3,63 µg L-1 para VOQ e 0,37 µg L-1 para VMOQ. Estes resultados mostram diferenças de até 2 ordens de grandeza de uma técnica para outra, que se não forem bem avaliados podem levar o analista a conclusões equivocadas.
Título en inglés
Statistic study of the analytical performance of DPV, SWV and MSWV electrochemical techniques for the reduction of the paraquat herbicide on an Au-UME and its analysis and quantification in pure and natural waters
Palabras clave en inglés
electrochemical techniques
natural waters
paraquat
statistic
Resumen en inglés
Statisctic studies of the analytical performance of Differential pulse voltammetry (DPV), Square wave voltammetry (SWV) and Multiple square wave voltammetry (MSWV) electrochemical techniques was performed for the electrochemical reduction of the paraquat herbicide on an gold ultramicroelectrode (Au-UME), aiming its analysis and quantification in pure and natural waters. The electrochemical reduction of paraquat was studied in 0.1 mol L-1 Na2SO4 support electrolyte in pH = 5.5 . The electrochemical responses showed two well-defined reduction peaks with potentials of -0.64 and -0.94 V vs Ag/AgCl 3.0 mol L-1 for peaks 1 and 2, respectively. The mathematical treatment was performed with data from peak 1, which is associated with a reversible solution reaction, where the electrode surface acts only as the electron transfer mediator. Working curves were obtained using the optimized experimental parameters in support electrolyte prepared with high purity water. To DPV, SWV and MSWV, the detection limits found for the peak currents associated to peak 1 were: 55.35 ± 0.18 µg L-1, 37.50 ± 0.32 µg L-1 and 21.42 ± 0.51 µg L-1, respectively. An analogous analytical procedure was applied in water samples collected in Mogi-Guaçu River, in São Carlos County, state of São Paulo. The variation in slope values, between curves obtained from pure water and those from river waters were practically depreciable for the three analytical methods, showing that the organic components and others contaminants present in natural waters caused only a minor interference in the measurements. The lower measurable values for paraquat in water samples were smaller than the allowed maximum of residue established by the Brazilian legislation for waste waters (100 µg L-1), indicating the developed methodology as convenient to such application. Calculations of detection and quantification limits, the evaluation of experimental errors and the limits of confidence were performed by the statistical procedure reported by Miller & Miller. The obtained detection limits values present a true physical significance, in a realistic order of magnitude, as they were determined by interpolation of the experimental analytical curves. The same analytical curves were submitted to the IUPAC methodology yielding the values of 29.43, 3.63 and 0.37 µg L-1 para DPV, SWV and MSWV, respectively, for pure water measurements. These results showed a difference up to two orders of magnitude from those obtained by the statistical methodology and may promote false conclusions, if not properly evaluated.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2008-04-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.