Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.75.2008.tde-15092008-114350
Document
Auteur
Nom complet
Carolina Maria Fioramonti Calixto
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2008
Directeur
Jury
Cavalheiro, Eder Tadeu Gomes (Président)
Fertonani, Fernando Luis
Zanoni, Maria Valnice Boldrin
Titre en portugais
Desenvolvimento e aplicação de eletrodos compósitos à base de grafite e Araldite®
Mots-clés en portugais
eletrodos compósitos de grafite-Araldite®
formulações farmacêuticas
técnicas eletroanalíticas
Resumé en portugais
A confecção e avaliação do desempenho voltamétrico de eletrodos compósitos à base de resina epóxi comercial Araldite ® utilizada como fase aglutinante e pó de grafite como fase condutora, na confecção dos eletrodos compósitos foi realizada. A resina foi preparada seguindo instruções do fabricante e adicionada a uma quantidade de pó de grafite para obter eletrodos contendo 50, 60 e 70% de grafite (m/m). Tais compósitos foram caracterizados fisicamente quanto à reprodutibilidade da resposta voltamétrica, resistência ôhmica e área efetiva em função da composição grafite/Araldite ®, sendo 70% (grafite, m/m) a que ofereceu melhores resultados, em termos de repetibilidade de resposta e corrente de pico. O teor real de grafite foi determinado por termogravimetria. Os intervalos úteis de potenciais para uso dos eletrodos compósitos também foram avaliados em diferentes eletrólitos. Finalmente, os eletrodos compósitos foram avaliados na determinação de atenolol, uma droga antihipertensiva, e dopamina, um neurotransmissor central do grupo das catecolaminas. Em todos os casos, o eletrodo compósito foi mais sensível na determinação dos dois analitos, quando comparado ao eletrodo de carbono vítreo. A dopamina foi determinada por voltametria de pulso diferencial (DPV). O limite de detecção foi de 0,61 µmol L-1e a resposta linear foi observada no intervalo de 4,0 a 95 µmol L-1. Os resultados obtidos na determinação da dopamina em formulação farmacêutica concordaram com os resultados obtidos com o método comparativo cromatografia líquida de alta eficiência (HPLC), com 95% de confiança. O atenolol também foi determinado por DPV, com limite de detecção da ordem de 2,23 µmol L-1, com resposta linear entre 4,45 e 84,7 µmol L-1. A determinação de atenolol, em formulações farmacêuticas, apresentou resultados que concordam com o método comparativo HPLC, com 95% de confiança. O atenolol também foi determinado em amostras de águas naturais, com recuperações entre 92 e 115%.
Titre en anglais
Development and apllication of composite electrode graphite-Araldite®
Mots-clés en anglais
composite electrode graphite-Araldite®
eletroanalytical techniques
pharmaceutical formulations
Resumé en anglais
The development and evaluation of the voltammetric behavior of composite electrodes prepared with graphite as a conducting phase and commercial epoxy resin Araldite ® as an insulating phase was performed. The resin was prepared according to instructions of the manufacturer and mixed with a suitable amount of graphite in order to prepare composites with 50, 60 and 70% of graphite (w/w). The composites were characterized in relation to their reproducibility of the cyclic voltammetric response, ohmic resistance, and repeatability of the effective area as a function of the Araldite ®/graphite ratio. The best repeatability of area as well as the higher peak currents was obtained with the 70% (graphite, w/w) composition using K3[Fe(CN)6] in KCl medium. The useful potential windows were also evaluated in different supporting electrolytes and pH ranges. Finally the composite electrodes were applied in the determination of the anti-hypertensive atenolol and the cathecolamine neurotransmitter dopamine. The composite electrodes were more sensitive to both analytes when compared to the glassy carbon. Dopamine was determined using differential pulse voltammetry (DPV) with linear dynamic range between 4.0 and 95 µmol L-1 and limit of detection 0.61 µmol L-1. The results agreed with those from high performance liquid chromatography (HPLC) within a 95% confidence interval. Atenolol was also determined by DPV with a 4.45 - 84.7 µmol L-1 linear range and 2.23 µmol L-1. The determination of atenolol in pharmaceutical formulations agreed with the HPLC method in a 95 % confidence interval. When applied to natural water samples spiked with the analyte, recoveries of 92 to 115% were found.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
CarolinaCalixtoR.pdf (4.70 Mbytes)
Date de Publication
2008-09-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.