• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.75.2007.tde-15052007-084924
Documento
Autor
Nombre completo
Sidney Xavier dos Santos
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2007
Director
Tribunal
Cavalheiro, Eder Tadeu Gomes (Presidente)
Fatibello Filho, Orlando
Polito, Wagner Luiz
Título en portugués
"Aplicação de eletrodos compósitos a base de grafite e borracha de silicone na determinação de substâncias de interesse farmacológico"
Palabras clave en portugués
eletrodo compósito de grafite e borracha de silicone
formulações farmacêuticas
voltametria
Resumen en portugués
Este trabalho tem por objetivo realizar estudos sobre as potenciais aplicações do compósito a base de grafite e borracha de silicone como material eletródico. O compósito foi aplicado na determinação de propranolol, uma droga antihipertensiva largamente utilizada no Brasil e rutina, um flavonóide com propriedades vasodilatadoras e antioxidantes. Os eletrodos foram preparados misturando-se proporções adequadas de pó de grafite e borracha de silicone, de maneira a obter um compósito com 70% de grafite (m/m). Dados de voltametria cíclica (CV) foram usados para estimar a região útil de trabalho para o eletrodo em diferentes eletrólitoes suporte e pH. Estudos usando CV foram utilizados para avaliar a resposta e o comportamento voltamétrico dos analitos propostos em relação a vários parâmetros. Para a quantificação foi utilizada voltametria de pulso diferencial (DPV), na qual foram obtidas curvas analíticas para definição de intervalos lineares de resposta e limites de detecção. Curvas analíticas também foram obtidas com eletrodo de carbono vítreo para comparação. Posteriormente, os procedimentos foram aplicados na determinação dos analitos em formulações farmacêuticas. Os resultados obtidos foram comparados com procedimentos padrão descritos na literatura. A rutina foi determinada no medicamento Novarrutiva e os resultados obtidos concordaram com o método de comparação com 95% de confiança. O propranolol foi determinado no medicamento Propranolol Ayerst? e os resultados concordaram com o método comparativo com 95% de confiança. Em todos os casos, com o eletrodo compósito foi obtido menor limite de detecção e maior região linear de resposta para os dois analitos, quando comparado ao eletrodo de carbono vítreo.
Título en inglés
"Application of composite silicone rubber based graphite electrode in determination of pharmacological interest substances"
Palabras clave en inglés
graphite silicone rubber composite
pharmaceutical formulation
voltammetry
Resumen en inglés
Studies regarding the applications of a graphite-silicone rubber composite as an electrode material have been performed and the results described in this work. The composite was used in the voltammetric determination of propranolol, an antihypertensive drug widely used in Brazil and rutin a flavonoid that presents both dilatation of blood vessels capabilities and antioxidative actions. The electrodes were prepared by using a suitable amount of graphite powder and silicone rubber in order to reach a 70% (graphite, w/w) composition. Cyclic voltammetric (CV) data were used in order to characterize the electrode material regarding useful potential window in different supporting electrolyte and pH. CV data were also used in order to evaluate the response of the composite electrode to the analytes. The quantitative measurements were performed with differential pulse voltammetry (DPV) with which analytical curves were obtained and used to estimate the detection limits and linear dynamic range. These data guided us towards the determination of the analytes in pharmaceutical formulations. The results were compared with those from standard methods with agreement in the 95% confidence level, according to the Student?s t-Test, in both cases. Lower limits of detection and larger linear dynamic ranges were observed for the composite when compared with those from the glassy carbon electrode under the same experimental conditions.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
SidneyXdosSantosR.pdf (2.95 Mbytes)
Fecha de Publicación
2007-05-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.