• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.75.2007.tde-15052007-084924
Document
Author
Full name
Sidney Xavier dos Santos
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2007
Supervisor
Committee
Cavalheiro, Eder Tadeu Gomes (President)
Fatibello Filho, Orlando
Polito, Wagner Luiz
Title in Portuguese
"Aplicação de eletrodos compósitos a base de grafite e borracha de silicone na determinação de substâncias de interesse farmacológico"
Keywords in Portuguese
eletrodo compósito de grafite e borracha de silicone
formulações farmacêuticas
voltametria
Abstract in Portuguese
Este trabalho tem por objetivo realizar estudos sobre as potenciais aplicações do compósito a base de grafite e borracha de silicone como material eletródico. O compósito foi aplicado na determinação de propranolol, uma droga antihipertensiva largamente utilizada no Brasil e rutina, um flavonóide com propriedades vasodilatadoras e antioxidantes. Os eletrodos foram preparados misturando-se proporções adequadas de pó de grafite e borracha de silicone, de maneira a obter um compósito com 70% de grafite (m/m). Dados de voltametria cíclica (CV) foram usados para estimar a região útil de trabalho para o eletrodo em diferentes eletrólitoes suporte e pH. Estudos usando CV foram utilizados para avaliar a resposta e o comportamento voltamétrico dos analitos propostos em relação a vários parâmetros. Para a quantificação foi utilizada voltametria de pulso diferencial (DPV), na qual foram obtidas curvas analíticas para definição de intervalos lineares de resposta e limites de detecção. Curvas analíticas também foram obtidas com eletrodo de carbono vítreo para comparação. Posteriormente, os procedimentos foram aplicados na determinação dos analitos em formulações farmacêuticas. Os resultados obtidos foram comparados com procedimentos padrão descritos na literatura. A rutina foi determinada no medicamento Novarrutiva e os resultados obtidos concordaram com o método de comparação com 95% de confiança. O propranolol foi determinado no medicamento Propranolol Ayerst? e os resultados concordaram com o método comparativo com 95% de confiança. Em todos os casos, com o eletrodo compósito foi obtido menor limite de detecção e maior região linear de resposta para os dois analitos, quando comparado ao eletrodo de carbono vítreo.
Title in English
"Application of composite silicone rubber based graphite electrode in determination of pharmacological interest substances"
Keywords in English
graphite silicone rubber composite
pharmaceutical formulation
voltammetry
Abstract in English
Studies regarding the applications of a graphite-silicone rubber composite as an electrode material have been performed and the results described in this work. The composite was used in the voltammetric determination of propranolol, an antihypertensive drug widely used in Brazil and rutin a flavonoid that presents both dilatation of blood vessels capabilities and antioxidative actions. The electrodes were prepared by using a suitable amount of graphite powder and silicone rubber in order to reach a 70% (graphite, w/w) composition. Cyclic voltammetric (CV) data were used in order to characterize the electrode material regarding useful potential window in different supporting electrolyte and pH. CV data were also used in order to evaluate the response of the composite electrode to the analytes. The quantitative measurements were performed with differential pulse voltammetry (DPV) with which analytical curves were obtained and used to estimate the detection limits and linear dynamic range. These data guided us towards the determination of the analytes in pharmaceutical formulations. The results were compared with those from standard methods with agreement in the 95% confidence level, according to the Student?s t-Test, in both cases. Lower limits of detection and larger linear dynamic ranges were observed for the composite when compared with those from the glassy carbon electrode under the same experimental conditions.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
SidneyXdosSantosR.pdf (2.95 Mbytes)
Publishing Date
2007-05-15
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.