• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.75.2007.tde-15012008-114604
Document
Author
Full name
Álvaro José dos Santos Neto
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2007
Supervisor
Committee
Lancas, Fernando Mauro (President)
Oliveira, Regina Vincenzi
Santoro, Maria Ines Rocha Miritello
Siqueira, Maria Elisa Pereira Bastos de
Tavares, Marina Franco Maggi
Title in Portuguese
Cromatografia líquida multidimensional e espectrometria de massas em tandem para análise direta de fármacos em fluidos biológicos: da escala convencional à miniaturizada
Keywords in Portuguese
análise de fármacos
cromatografia líquida multidimensional
meios de acesso restrito
Abstract in Portuguese
A análise de fármacos e outras moléculas relacionadas em fluidos biológicos é essencial no âmbito farmacêutico. Atualmente, a demanda por análises rápidas e mais complexas impulsiona a química analítica para o desenvolvimento de soluções inovadoras. A cromatografia líquida multidimensional com acoplamento de colunas para injeção direta de fluidos biológicos tem ganhado atenção nos últimos anos. Ao mesmo tempo, o acoplamento entre cromatografia líquida e espectrometria de massas proporcionou marcante desenvolvimento científico na área biomédica e bioquímica. Esta tese apresenta os diversos estágios na redução da escala em sistemas de column switching utilizando colunas RAM, para a análise de fármacos em fluidos biológicos. Na escala convencional, com colunas de 4,6 mm de diâmetro interno, desenvolveu-se um sistema para a análise de fluoxetina em plasma. A metodologia desenvolvida foi adequadamente validada para aplicação na monitorização terapêutica, com tempo de análise de 20 minutos (incluído o preparo de amostras) e consumo de apenas 100 µL de amostra. Avaliou-se a escala microbore (2,1 mm), a qual apresentou excelente potencialidade para o acoplamento com a espectrometria de massas utilizando ionização por electrospray. Na primeira etapa em escala capilar, com colunas de 520 µm de diâmetro interno, desenvolveu-se um sistema para análise de fluoxetina em plasma. Esse sistema proporcionou análises em 25 minutos, também aplicáveis à monitorização terapêutica, consumindo poucos microlitros de amostra. Finalmente, foi desenvolvido um sistema de column switching capilar com colunas na ordem de 200 µm. Esse sistema foi acoplado à espectrometria de massas em tandem proporcionando, inovadoramente, análises altamente sensíveis e simultâneas, com baixo consumo de amostras. Um grupo de cinco antidepressivos e o albendazol, com seus produtos de biotransformação, tiveram suas análises validadas em menos de 8 minutos, consumindo menos de um microlitro de amostra. Esse sistema capilar contrasta com os sistemas convencionais comumente utilizados, os quais consomem entre centenas e milhares de vezes mais amostra para atingir a mesma detectabilidade.
Title in English
Multidimensional liquid chromatography and tandem mass spectrometry for the direct analysis of grugs in biofluids: from the conventional to the miniaturized scale
Keywords in English
drug analysis
multidimensional liquid chromatography
restricted access media
Abstract in English
Analysis of drugs and other related molecules in biofluids is essential in the pharmaceutical field. Nowadays, the development of innovative solutions in analytical chemistry has been pushed by the needs for speed and more complex analysis. Lately, multidimensional liquid chromatography using column switching for direct injection of biofluids has gained attention. At the same time, liquid chromatography hyphenated with mass spectrometry provided remarkable scientific development in biomedical and biochemical area. This thesis presents the scale reduction steps in RAM column switching, for drug analysis in biofluids. In the conventional scale, using 4.6 mm i.d. columns, a system was developed, providing fluoxetine analysis in plasma. The developed method resulted in a 20 min long run, including the sample preparation step, which consumed 100 µL of sample. The method was adequately validated, being applicable to therapeutic drug monitoring. The microbore scale (2.1 mm) was evaluated, presenting great potentiality for coupling with electrospray-mass spectrometry. In the first capillary scale step, using 520 µm columns, a system was developed for fluoxetine analysis. Fluoxetine analysis was achieved in 25 min, within the application range for therapeutic drug monitoring, and consuming few microliters of sample. Finally, a RAM capillary column switching system employing columns on the order of 200 µm was developed, in an innovative way. This system was coupled with a tandem mass spectrometer, rendering sensitive and simultaneous analysis with reduced sample volume. The analysis of one group containing five antidepressants, as well as the analysis of albendazol and its metabolites was validated. These analyses took only 8 minutes and consumed less than one microliter of sample. In contrast with conventional systems, this system consumes about hundreds or thousands times less sample, with the same detectability.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
AlvaroJSN.pdf (4.90 Mbytes)
Publishing Date
2008-01-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.