Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.75.2007.tde-14092007-153242
Document
Auteur
Nom complet
Michele Odnicki da Silva
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2007
Directeur
Jury
Machado, Sergio Antonio Spinola (Président)
Carlos, Ivani Aparecida
Vaz, Carlos Manoel Pedro
Titre en portugais
Desenvolvimento e caracterização de eletrodos com base no níquel para a determinação de etanol
Mots-clés en portugais
eletrodeposição
etanol
niquel
Resumé en portugais
No presente trabalho foi proposta a construção de eletrodos de níquel e algumas ligas (Sn, Ru), assim como de materiais nanoestruturados, para a determinação de etanol em amostras de bebidas e medicamentos. Para isto, foram utilizadas técnicas como a voltametria cíclica, a cronoamperometria, a espectroscopia de impedância eletroquímica, a microscopia de força atômica e a microscopia de transmissão. O eletrodo da liga Ni-Sn foi preparado por eletrodeposição, utilizando um banho de Watts contendo 6,25 g de NiCl2.6H2O e 0,5 g de SnCl2.2H2O em 25 mL de solução aquosa. Os depósitos foram modificados com RuO2, utilizando uma solução RuCl3 0,1 M. O eletrodo da liga foi deixado na solução em banho de ultrasson e posteriormente aquecido a 400ºC em forno em presença de oxigênio, para a decomposição térmica. O Ni nanoestruturado foi preparado a partir de uma solução contendo 1,8 g NiCl2.6H2O dissolvido em 30 mL etanol, adicionando uma mistura de 3,5 g de Zn em pó e 10 mL de aminoetanol, em agitação. A separação do pó preto foi feita com uma placa magnética. Para a confecção do eletrodo foi adicionada uma alíquota 10 mL da solução contendo o pó, náfion e etanol, na superfície do eletrodo de grafite pirolítico. Os perfis voltamétricos foram analisados em meio de hidróxido de sódio 0,5 M, podendo-se assim observar as reações de oxi-redução característica do Ni, da liga Ni-Sn, da liga modificada com RuO2 e da nanoestrutura. Foi utilizado intervalo de potencial de 100 a 700 mV com velocidade de 50 mVs-1. As medidas de impedância eletroquímica foram realizadas em sistemas com etanol com o intuito único de demonstrar a presença de um loop indutivo, que pode ser associado à transformação óxido superior/óxido inferior na superfície do eletrodo. Este loop foi observado para os eletrodos de Ni e liga, não sendo muito evidente para o eletrodo modificado com RuO2. Foram realizadas medidas de AFM para a caracterização topográfica dos eletrodos, mostrando a diferença entre as superfícies, indicando que o Ni liso foi modificado com o eletrodepósito da liga Ni-Sn e que esta também foi modificada pela deposição do RuO2. A morfologia da nanoestrutura foi observada por microscopia eletrônica de transmissão, podendo observar que se obtiveram estruturas de níquel em escala nanométrica. Os eletrodos foram utilizados na determinação de etanol em meio de NaOH 0,5 mol L-2, com a construção de curvas analíticas pelo método da adição consecutiva de alíquotas de etanol, a partir de uma solução estoque. Após a curva analítica ser levantada, foram feitos os tratamentos estatísticos obtendo-se os valores para os limites de detecção e quantificação. Com o eletrodo Ni nanoestruturado obteve-se o melhor resultado sendo este empregado na determinação de etanol nas amostras de conhaque, cachaça e enxaguante bucal, utilizando a técnica de cronoamperometria. A excelente porcentagem de recuperação obtida mostrou que o efeito da matriz, nestas determinações, é praticamente desprezível, o que está de acordo com o mecanismo da reação de oxidação do etanol sobre Ni, fortemente catalisado pela superfície dos eletrodos em estudo.
Titre en anglais
Development and characterization of nickel-based electrodes for the ethanol determination
Mots-clés en anglais
electrodeposition
ethanol
nickel
Resumé en anglais
This objective of this work is related to the development of nickel and some nickel-alloys electrodes, as well as some nanostructured nickel surfaces, for ethanol determinations in drinks and in pharmacological formulations. For this, some experimental techniques were employed, as cyclic voltammetry, cronoamperometry, electrochemical impedance spectroscopy, atomic force microscopy and transmission microscopy. The Ni-Sn alloy electrode was prepared by electrodeposition from a Watts bath containing 6,25 g NiCl2.6H2O and 0,5 g SnCl2.2H2O and water in order to produce 25 mL of aqueous solution. The electrodeposits were further modified with RuO2 obtained from a 0.1 mol L-1 RuCl3 solution. The Ni-Sn alloy electrode were allowed in the ruthenium solution in ultrasonic bath and further heated to 400 oC in the presence of oxygen, in order to promote the thermal decomposition of ruthenium chloride. The nanostructured Ni surface was obtained from a chemical deposition in a solution composed by 1.8 g NiCl2.6H2O dissolved in 30 mL ethanol and adding 3.5 g of powdered Zn and 10 mL of aminoethanolic solution, under mechanical stirring. The black powder precipitated was separated by a magnetic rod. In order to prepare the electrode, with such powder, a 10 mL aliquot of solution containing the Ni powder, Nafion® and ethanol were dipped in a pirolitic graphite surface and allowed to dry. The voltammetric profiles were analyzed in order to evaluate the oxireduction characteristics of Ni surfaces, as well as the Ni-Sn alloy and the RuO2 modified surfaces and the nanostructured one. A potential window between 100 and 700 mV was scanned at 50 mV s-1, in 0.5 mol L-1 NaOH electrolyte. The electrochemical impedance spectroscopy measurements were performed in electrolytes containing ethanol, in order to observe the presence of an inductive loop, which has been associated to the low/high valences Ni oxides formed during ethanol oxidation on such surfaces. This loop was quite evident in Ni surfaces but not on the surfaces modified with RuO2. AFM measurements were performed in order to obtain the topological characteristics of the surfaces, indicating the eventual alterations associated with the RuO2 modifications. The nanostructures morphology was investigated by transmission microscopy were the nanometric dimensions of Ni phases were evident. The developed electrodes were applied in ethanol determinations in 0.5 mol L-1 NaOH solutions, prepared with Milli-Q water. The successive standard additions were used to obtain an analytical plot. After the analytical plot has been obtained, statistical analyses were performed, in order to determine the detection and quantification limits, as well as the errors involved in such determinations. As the Ni nanostructured electrodes yielded the best results, it was used in the determination of ethanol in samples of cognac, "aguardente" (sugar cane distilled drink) and mouthwash liquids, using chronoamperometry. The excellent recoveries percentages obtained showed that the matrix effect, in such determinations, was almost depreciable. This is related with the high catalytic power of Ni surfaces towards the ethanol oxidation reaction.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
MicheleOdnicki.pdf (1.85 Mbytes)
Date de Publication
2007-09-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.