Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.75.2010.tde-12082010-081524
Documento
Autor
Nome completo
Janete Rodrigues Gonçalves
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2010
Orientador
Banca examinadora
Reis, Boaventura Freire dos (Presidente)
Carrilho, Emanuel
Kamogawa, Marcos Yassuo
Título em português
Estudo da viabilidade da fotometria em fase sólida empregando multicomutação em fluxo, cela de fluxo com caminho óptico de 3mm e fotômetro de LED
Palavras-chave em português
Cobalto
Fotometria em fase sólida
Multicomutação em fluxo
Resumo em português
No presente trabalho foi estudada a viabilidade da fotometria em fase sólida usando cela de fluxo com caminho óptico de 3 mm e fotômetro de LED, para determinação de cobalto em suplementos vitamínicos digeridos em meio ácido. O método automatizado foi baseado na formação de um composto de cobalto(II) com o reagente cromogênico 1-(2'-tiazolilazo)-2-naftol (TAN) retido em suporte sólido quimicamente modificado (C18) monitorado em 580 nm. O módulo de análise foi baseado no processo de multicomutação em fluxo. Após a definição das variáveis de controle, as amostras digeridas em meio ácido foram processadas. O procedimento permitiu a determinação de cobalto na faixa linear de 0,05 a 2,0 mg L-1. A precisão analítica, expressa como DPR, foi de 4,2% (n = 9) e freqüência de amostragem de 17 determinações por hora foram observadas. Os limites de detecção e quantificação foram estimados em 0,0166 e 0,055 mg L-1, respectivamente.
Título em inglês
Study of the feasibility of using solid-phase photometry employing multicommutation, flow cell with 3mm optical path and LED photometer
Palavras-chave em inglês
Cobalt
Multicomutation
Solid-phase spectrophotometry
Resumo em inglês
In the present work the viability of the solid phase photometry using a flow cell with optical pathway of 3 mm and a LED photometer for the determination o cobalt vitamin supplements digested in acidic medium was studied. The method automated was based on the compound formation of cobalt and the chromomeric reagent 1-(2'-tiazolilazo)-2-naftol (TAN), which was immobilized on a solid support (C18) and monitored at 580 nm. The analysis module was based on the multicommutation flow analysis process. After definition of the variables control, samples digested in acid medium ware analyzed. The procedure allowed cobalt determination within the linear range 0.0 up to 2.0 mg L-1. The analytical precision, expressed as DPR, was 4.2 %, and the analytical frequency was 17 determinations per hour. Limit of detection and limit of determination were 0.0166 and 0.055 mg L-1, respectively.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2010-12-01
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.