• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.75.2003.tde-02102004-121100
Document
Author
Full name
Aline Segnini
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2003
Supervisor
Committee
Cavalheiro, Eder Tadeu Gomes (President)
Chierice, Gilberto Orivaldo
Gomes Neto, José Anchieta
Title in Portuguese
"Uso de pirrolidinoditiocarbamatos de manganês(II) e vanadila na preparação e aplicação de eletrodos de pasta de carbono modificados"
Keywords in Portuguese
ditiocarbamatos
eletrodos de pasta de carbono modificados
voltametria cíclica
Abstract in Portuguese
Devido à sua baixa solubilidade em água, os pirrolidinoditiocarbamatos poderiam produzir eletrodos livres do problema de lixiviação do modificador, os quais poderiam ser usados como detectores amperométricos, em análises em fluxo e outros procedimentos hidrodinâmicos. O complexo poderia agir como um intermediário de transferência de elétrons entre o analito e a superfície eletródica, aumentando a sensibilidade da resposta analítica do sensor. Desta forma, eletrodos de pasta de carbono modificados (EPCM) com complexos de pirrolidinoditiocarbamatos anidros de diversos metais foram preparados e testados quanto à sua aplicação em técnicas voltamétricas. Os complexos de manganês(II), [MnPyr2] e cobalto(II), [CoPyr2], foram os que apresentaram os melhores resultados em termos de estabilidade e reprodutibilidade de resposta, escolhendo-se o EPCM-[MnPyr2], para uso neste trabalho. O desempenho do eletrodo foi avaliado usando voltametria cíclica, cronoamperometria e análise em fluxo, com detecção amperométrica de peróxido de hidrogênio apresentando regiões lineares de 1,25-14,8; 0,5-41; 1,0-75 x 10-4 mol L-1 e limites de detecção de 11,2; 2,98; 5,40 x 10-5 mol L-1 respectivamente para cada técnica. Na determinação de peróxido de hidrogênio em amostra de alvejante comercial observou-se concordância nos resultados obtidos em voltametria cíclica e análise em fluxo, usando o eletrodo proposto em comparação com a permanganometria clássica, com 95 % de intervalo de confiança. Estes resultados foram obtidos após otimização de parâmetros como velocidade de varredura, pH, eletrólito suporte, entre outros. A oxidação ocorre por meio de um processo eletrocatalítico. O desempenho do pirrolidinoditiocarbamato de vanadila hidratado também foi avaliado como alternativa aos ditiocarbamatos anidros, na preparação de eletrodos modificados com esta classe de complexos, considerando que os complexos hidratados seriam mais fáceis de preparar. Entretanto uma baixa estabilidade e reprodutibilidade de resposta foi observada. O [MnPyr2] mostrou comportamento no qual ocorre oxidação, concordando com a proposta de Schrauzer para ligantes do tipo ímpar, apesar de que a oxidação só ocorreu na presença de oxidantes fortes, como o peróxido de hidrogênio.
Keywords in English
cyclic voltammetry
dithiocarbamates
modified carbon paste electrode
Abstract in English
Considering their low solubility in water, the dithiocarbamate complexes should produce electrodes without problems of modifier leaching. Such electrodes could be used as amperometric detectors in flow injection analysis and hydrodynamic methods. The complex should act as an electron transfer mediator between the analyte and the electrode surface, improving the response sensitivity of the sensor. Considering these statements carbon paste electrodes modified (EPCM) with anhydrous pyrrolidinedithiocarbamates of several metals were prepared and evaluated in relation to their possible application in voltammetric techniques. Best results regarding response stability and reproducibility were obtained with manganese(II), [MnPyr2] and cobalt(II), [CoPyr2] complexes. The first one was chosen to develop the present work. The electrode performance was evaluated in cyclic voltammetry, chrono amperometric and flow injection analysis with amperometric detection. Linear dynamic ranges of 1,25-14,8; 0,5-41; 1,0-75 x 10-4 mol L-1 and limits of detection of 11,2; 2,98; 5,40 x 10-5 mol L-1 were found respectively for each technique in the determination of hydrogen peroxyde. The methods were used for the determination of H2O2 in bleaching formulation and presented agreement with the classical titration with potassium permanganate within 95% confidence level. Such results have been obtained after optimization of experimental parameters such as scan rate, pH, supporting electrolyte, and others. The oxidation occurred by an electrocatalytic process. Finally the performance of a carbon paste electrode modified with a hydrated vanadyl pyrrolidinedithiocarbamate complex was evaluated as an alternative to the anhydrous complex in the preparation of the modified electrode, since the hydrated complexes are easier to prepare. However a low response stability and reproducibility have been observed. The [MnPyr2] presented an oxidation behavior in agreement with Schrauzer’s predictions, although the oxidation of the metal center occurred only in the presence of strong oxidative agents as the hydrogen peroxide.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
2sumario.pdf (132.23 Kbytes)
3paginaspretextuais.pdf (195.40 Kbytes)
4introducao.pdf (228.38 Kbytes)
5parteexperimental.pdf (158.83 Kbytes)
6resultados.pdf (539.37 Kbytes)
7Conclusao.pdf (60.83 Kbytes)
Publishing Date
2006-03-24
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.